Example 5: from batch to SMB on real equipment
The UD operating parameters are dimensionless, so one operating point can be run as a batch process or as a simulated moving bed. This example turns one point into the injection volume and cut time of a batch column, and into the flow rates and switch time of a four-zone SMB unit built from the same columns.
Theory: From parameters to equipment · Symbols: Notation · Interactive: Design tool
The system and the question
The linear system of the simple example, \(H_1 = 1.5\) and \(H_2 = 2.5\), with 1.5 g/L of component 1 and 1 g/L of component 2 in the feed, under ideal conditions. The columns have \(V_{\mathrm{col}} = 100\) mL and total porosity \(\varepsilon = 0.6\): 60 mL of liquid and 40 mL of stationary phase. The batch column runs at \(Q = 10\) mL/min, so
\[ \begin{aligned} t_0 &= \frac{\varepsilon V_{\mathrm{col}}}{Q} = 6.0\ \text{min} , \\ F &= \frac{1 - \varepsilon}{\varepsilon} = 0.667 . \end{aligned} \]The operating point is \((s_{\mathrm{cut}}, s^{\mathrm{FF}}) = (1.75, 0.5)\). It lies inside the triangle of complete separation, \(H_1 \le s_{\mathrm{cut}} \le H_2 - s^{\mathrm{FF}}\), in the middle of the cut window \(1.5 \le s_{\mathrm{cut}} \le 2.0\).
- Batch: how long and how much to inject, and when to cut?
- SMB with one column per zone, \(\Delta t_{\mathrm{switch}} = 5\) min, and \(s_{\mathrm{I}} = 2.75\), \(s_{\mathrm{IV}} = 1.25\) for zones I and IV: the zone flows and the external flows?
- Do the two processes give the same products?
Solution
Step 1: the batch run
The definitions of the Theory page, solved for the times. The fresh feed is a fixed-bed event,
\[ s^{\mathrm{FF}} = \frac{Q\,\Delta t^{\mathrm{FF}}}{(1 - \varepsilon)V_{\mathrm{col}}} = \frac{\Delta t^{\mathrm{FF}}}{t_0}F^{-1} , \] \[ \Delta t^{\mathrm{FF}} = s^{\mathrm{FF}}\, t_0 F = 2.0\ \text{min} , \]so the injection is \(Q\,\Delta t^{\mathrm{FF}} = 20\) mL. The cut is measured from the end of the column feed; in batch elution the column feed is the fresh feed, \(\Delta t^{\mathrm{F}} = \Delta t^{\mathrm{FF}}\):
\[ s_{\mathrm{cut}} = \frac{Q\left(t_{\mathrm{cut}} - \Delta t^{\mathrm{F}}\right) - \varepsilon V_{\mathrm{col}}}{(1 - \varepsilon)V_{\mathrm{col}}} , \] \[ t_{\mathrm{cut}} = \Delta t^{\mathrm{FF}} + t_0\left(1 + F s_{\mathrm{cut}}\right) = 15.0\ \text{min} . \]Component 1 leaves the column from \(t_0(1 + F H_1) = 12.0\) to 14.0 min, component 2 from 16.0 to 18.0 min. The cut at 15.0 min lies in the middle of the gap, and both products are 100 % pure with 100 % yield: each injection gives 30 mg of component 1 and 20 mg of component 2. With stacked injections the next injection follows every 6.0 min (\(s_{\mathrm{cycle}} = 1.5\)).
Step 2: the SMB unit at the same point
In the classical four-zone SMB, the same operating point sets zones II and III. With one SMB event per cycle, \(N_{\mathrm{SMB}} = 1\), the auxiliary parameter of zone II is \(S_{\mathrm{II}} = s_{\mathrm{II}} + s^{\mathrm{FF}}\), and the feed enters between zones II and III, so
\[ \begin{aligned} s_{\mathrm{II}} &= s_{\mathrm{cut}} = 1.75 , \\ s_{\mathrm{III}} &= S_{\mathrm{II}} = s_{\mathrm{II}} + s^{\mathrm{FF}} = 2.25 . \end{aligned} \]Zones I and IV must regenerate the adsorbent and the eluent, \(s_{\mathrm{I}} \ge H_2\) and \(s_{\mathrm{IV}} \le H_1\); the chosen \(s_{\mathrm{I}} = 2.75\) and \(s_{\mathrm{IV}} = 1.25\) keep a margin of 0.25 from each limit. Each zone flow follows from the definition of the SMB parameter (Theory page), solved for \(Q_j\):
\[ s_j = \frac{Q_j\,\Delta t_{\mathrm{switch}} - \varepsilon V_{\mathrm{col}}}{(1 - \varepsilon)V_{\mathrm{col}}} , \]so
\[ Q_j = \frac{\varepsilon V_{\mathrm{col}} + (1 - \varepsilon)V_{\mathrm{col}}\, s_j}{\Delta t_{\mathrm{switch}}} , \]here \(Q_j = (60\ \text{mL} + 40\ \text{mL} \times s_j)/(5\ \text{min})\).
In the time form of this definition, \(s_j = (\Delta t_{\mathrm{switch}}/t_0 - 1)F^{-1}\), the dead time is the zone's own, \(t_0 = \varepsilon V_{\mathrm{col}}/Q_j\) (2.31 min in zone II), not the 6.0 min of the batch column. The zone conditions can be checked with the distance \(l_{j,k} = F(s_k - H_j)/(1 + F H_j)\), in column lengths, that the front of component \(j\) moves in zone \(k\) during one switch, the shift of the column included (simple example). The table gives \(l_{j,k}\) for the component named in the condition:
| Zone | \(s_j\) | \(Q_j\) (mL/min) | Condition | \(l_{j,k}\) |
|---|---|---|---|---|
| I | 2.75 | 34 | \(s_{\mathrm{I}} \ge H_2\) | 0.0625 |
| II | 1.75 | 26 | \(s_{\mathrm{II}} \ge H_1\) | 0.0833 |
| III | 2.25 | 30 | \(s_{\mathrm{III}} \le H_2\) | −0.0625 |
| IV | 1.25 | 22 | \(s_{\mathrm{IV}} \le H_1\) | −0.0833 |
- Zone I: component 2 is carried forward, so the adsorbent leaves the zone clean.
- Zone II: component 1 is carried forward, so none of it reaches the extract.
- Zone III: component 2 moves back, so none of it reaches the raffinate.
- Zone IV: component 1 moves back, so the eluent leaves the zone clean.
The external flows follow from the node balances: eluent \(Q^{\mathrm{EL}} = Q_{\mathrm{I}} - Q_{\mathrm{IV}} = 12\), extract \(Q^{\mathrm{E}} = Q_{\mathrm{I}} - Q_{\mathrm{II}} = 8\), fresh feed \(Q^{\mathrm{FF}} = Q_{\mathrm{III}} - Q_{\mathrm{II}} = 4\) and raffinate \(Q^{\mathrm{R}} = Q_{\mathrm{III}} - Q_{\mathrm{IV}} = 8\) mL/min. The balance closes: 12 + 4 = 16 mL/min in, 8 + 8 = 16 mL/min out. The feed per switch, \(Q^{\mathrm{FF}}\Delta t_{\mathrm{switch}} = 20\) mL, is \((1 - \varepsilon)V_{\mathrm{col}}\, s^{\mathrm{FF}}\), the same volume as one batch injection (Sainio 2021, Eq. 43).
Step 3: the same products
The batch run and the SMB unit share the operating point: \(s_{\mathrm{cut}} = s_{\mathrm{II}}\) and the same \(s^{\mathrm{FF}}\). Under ideal conditions the feasible regions of the two processes on the same \((s, S)\) operating parameter plane are identical, and at the same operating point both give the same purities: 100 % for both products here, at complete separation (Siitonen and Sainio 2015). Sainio (2021) showed that this holds for reduced purities as well. That is the transfer of design: an operating point found in batch experiments can be taken to the SMB as it is.
In practice two things differ. Dispersion and mass-transfer resistance act differently in the two processes, so the transfer is approximate; at the same column efficiency the SMB is usually less sensitive to them than the batch column (Sainio 2021; see Limits of the ideal picture). And the flow rates are not the same: zone I runs at 34 mL/min, 3.4 times the batch flow, so check the pressure limit of the columns. Pressure drop is not part of the ideal model.
Try it yourself
The design tool converts an operating point to times when the column is given: enter \(\varepsilon = 0.6\) and \(t_0 = 6\) min with the linear isotherm \(H_1 = 1.5\), \(H_2 = 2.5\), and put the operating point at (1.75, 0.5). The chromatogram on the time axis is Figure 1. The design tool in SMB mode shows the same operating point as a four-zone SMB.
Further reading
- Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.
- Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
- Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
- Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.