Skip to the content
Unified Design Method Design of chromatographic separation processes

Example 3: waste fraction

When the feed per injection is too large for one cut, the mixed middle of the chromatogram can be cut out and discarded. Both products are then pure again, at the price of yield. This example works out the cuts and the yields, and what recycling the waste would and would not change.

Theory: Waste and recycle fractions · Symbols: Notation · Interactive: Design tool

The system and the question

The system of Example 2: batch elution under ideal conditions, linear isotherms with \(H_1 = 1.5\) and \(H_2 = 2.5\), and the feed \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\) (g/L). This time the injection is larger, \(s^{\mathrm{FF}} = 1.4\), beyond the touching-bands limit \(H_2 - H_1 = 1.0\). Both products must be pure.

  1. Where are the bands, and where do they overlap?
  2. Where must the two cuts be, and how large is the waste fraction?
  3. What are the yields, and what does the waste cost?

Solution

Step 1: the overlap

Each band is a rectangle at its feed concentration on \(H_i - s^{\mathrm{FF}} \le s_{\mathrm{cut}} < H_i\) (Example 2, Step 1). Component 1 occupies \(0.1 \le s_{\mathrm{cut}} < 1.5\) at 1.5 g/L and component 2 \(1.1 \le s_{\mathrm{cut}} < 2.5\) at 1 g/L. They overlap on

\[ H_2 - s^{\mathrm{FF}} \le s_{\mathrm{cut}} < H_1 , \]

that is \(1.1 \le s_{\mathrm{cut}} < 1.5\), where the effluent has the feed composition. The gap between the bands, front of band 2 minus end of band 1, is \(H_2 - H_1 - s^{\mathrm{FF}} = -0.4\). No single cut can give pure products here, and not even 90 %/90 %: the 90 % region of Example 2 ends at \(s^{\mathrm{FF}} = 1.28\).

Step 2: two cuts and the waste fraction

Two cut events split the effluent into three fractions. Following Sainio (2021), call them \(s_{\mathrm{cut2}}\) (end of the first product, start of the waste) and \(s_{\mathrm{cut3}}\) (end of the waste, start of the second product). The first product is pure if it ends before band 2 begins, and the second if it begins after band 1 has ended:

\[ \begin{aligned} s_{\mathrm{cut2}} &\le H_2 - s^{\mathrm{FF}} , \\ s_{\mathrm{cut3}} &\ge H_1 . \end{aligned} \]

The smallest waste fraction takes both limits, \(s_{\mathrm{cut2}} = 1.1\) and \(s_{\mathrm{cut3}} = 1.5\): it is exactly the overlap. The difference of two cut events is a fixed-bed event (Event algebra), so the size of the waste fraction is an \(s_{\mathrm{FB}}\) value of its own:

\[ \begin{aligned} s^{\mathrm{W}} &= s_{\mathrm{cut3}} - s_{\mathrm{cut2}} \\ &= s^{\mathrm{FF}} - (H_2 - H_1) = 0.4 . \end{aligned} \]

On a real column it is a time and a volume. On the column of Example 5 (100 mL, \(\varepsilon = 0.6\), 10 mL/min, \(t_0 = 6\) min, \(F = (1 - \varepsilon)/\varepsilon = 2/3\)), the waste is collected for \(\Delta t^{\mathrm{W}} = s^{\mathrm{W}} t_0 F = 1.6\) min, that is 16 mL.

Figure 1. Outlet profile at \(s^{\mathrm{FF}} = 1.4\). The bands overlap on \(1.1 \le s_{\mathrm{cut}} < 1.5\). Cutting at 1.1 and 1.5 and sending the shaded middle to waste leaves two pure products.
Figure 2. The same run on the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) operating parameter plane, \(S_{\mathrm{cut}} = s_{\mathrm{cut}} + s^{\mathrm{FF}}\). A run with a waste fraction is two operating points, one per cut, both at the distance \(s^{\mathrm{FF}}\) from the diagonal. With the smallest waste they lie on the extensions of two sides of the complete-separation triangle: \(S_{\mathrm{cut2}} = H_2 = 2.5\) and \(s_{\mathrm{cut3}} = H_1\), with \(S_{\mathrm{cut3}} = 2.9\) (Sainio 2021, Fig. 6). The hollow points are the cuts for 90 % targets.

Step 3: yields

Each product loses the part of its band that lies in the overlap. With linear isotherms and pure products,

\[ \begin{aligned} Y_1 &= \frac{c_1^{\mathrm{FF}}\,(s_{\mathrm{cut2}} - H_1 + s^{\mathrm{FF}})}{c_1^{\mathrm{FF}}\, s^{\mathrm{FF}}} \\ &= \frac{H_2 - H_1}{s^{\mathrm{FF}}} = \frac{1.0}{1.4} , \end{aligned} \]

and the same for \(Y_2\): both yields are 71.4 %, whatever the feed concentrations, because both bands lose the same length 0.4. The waste holds 0.6 of component 1 and 0.4 of component 2 (per unit volume of stationary phase, in the unit of \(c\)), 28.6 % of each injected amount: it has the feed composition, 60 % component 1 and 40 % component 2.

With 90 % targets instead of 100 %, product 1 may keep 0.20 of the overlap and product 2 0.08 (Example 2, Step 3). The cuts move to \(s_{\mathrm{cut2}} = 1.30\) and \(s_{\mathrm{cut3}} = 1.42\), the waste shrinks to \(s^{\mathrm{W}} = 0.12\), and the yields rise to 85.7 % for product 1 and 77.1 % for product 2. The relaxed targets now favour the rich component 1.

What the waste costs

Compare the run with the largest injection that needs no waste, the touching-bands point of Example 2 (\(s^{\mathrm{FF}} = 1.0\), one cut at 1.5). Per cycle of stacked injections (Siitonen and Sainio 2011, Eq. 34) and per unit volume of stationary phase:

Pure productsOne cut, \(s^{\mathrm{FF}} = 1.0\)Waste fraction, \(s^{\mathrm{FF}} = 1.4\)
Yield of each product100 %71.4 %
Cycle length, \(s_{\mathrm{cycle}}\)2.02.4
Productivity per volume pumped, \(m_1/s_{\mathrm{cycle}}\)0.750.625 (−17 %)
Productivity per volume pumped, \(m_2/s_{\mathrm{cycle}}\)0.500.417 (−17 %)
Eluent consumption, \((s_{\mathrm{cycle}} - s^{\mathrm{FF}})/m_1\)0.6670.667
Eluent consumption, \((s_{\mathrm{cycle}} - s^{\mathrm{FF}})/m_2\)1.001.00

The larger injection makes the cycle longer, but every extra unit of feed beyond 1.0 ends up in the waste. Each product still receives what the touching-bands run gives it, 1.5 of component 1 and 1.0 of component 2 per cycle, so both productivities fall by 17 % and the eluent consumption stays the same. Under ideal conditions with linear isotherms the waste fraction is simply feed that has passed through the column (Sainio 2021, Section 5.1).

Feeding the waste back to the column with the next injection, steady-state recycling (SSR), does not rescue this run under ideal conditions. Example 8 takes this system and recycles the middle cut: with the same fresh feed \(s^{\mathrm{FF}} = 1.4\) and the same cuts, the recycle enlarges the column feed until the bands overlap more, and product 1 drops to 84.0 % purity at steady state (product 2 stays pure). Pure products with full yield need \(s^{\mathrm{FF}} = H_2 - H_1 = 1.0\) (Example 8, run B), which is no gain over batch elution at the tip of the triangle. In practice recycling pays off, because a real column can be run at a higher flow rate and recycling keeps the yield high as dispersion grows.

Try it yourself

In the design tool, enter the linear isotherm \(H_1 = 1.5\), \(H_2 = 2.5\), feed 1.5 and 1, and set \(s^{\mathrm{FF}} = 1.4\). The chromatogram shows the overlap of Step 1, and the profile type reports overlapping bands with a feed plateau.

Further reading

  1. Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
  2. Sainio, T., Kaspereit, M., Analysis of steady state recycling chromatography using equilibrium theory, Sep. Purif. Technol. 66 (2009) 9–18.
  3. Kaspereit, M., Sainio, T., Simplified design of steady-state recycling chromatography under ideal and nonideal conditions, Chem. Eng. Sci. 66 (2011) 5428–5438.
  4. Siitonen, J., Sainio, T., Explicit equations for the height and position of the first component shock for binary mixtures with competitive Langmuir isotherms under ideal conditions, J. Chromatogr. A 1218 (2011) 6379–6387.

Disclaimer: No liability is assumed for correctness or completeness of data generated with the tools available on this website.