Skip to the content
Unified Design Method Design of chromatographic separation processes

Theory · Symbols and the meaning of “ideal conditions”: Notation

Binary Langmuir isotherms: how the triangle distorts

With linear isotherms the complete-separation region is a right triangle, and its vertex is the operating point with the most feed per cycle. Preparative separations run at concentrations where the isotherms bend. The region then depends on the feed concentration: it shrinks, moves to smaller \(s_{\mathrm{cut}}\), one side curves, and the optimum moves to a new vertex, \(w\).

This page shows how and why, with formulas for the vertices \(w\) and \(r\) and the numbers for the reference system of the tools. Under ideal conditions batch elution and the classical four-zone SMB have the same complete-separation region (Siitonen and Sainio, 2015; Sainio, 2016). Everything here is therefore also a picture of the \((m_2, m_3)\) plane of Triangle Theory, with \(s_{\mathrm{cut}}\) in the role of \(m_2\) and \(S_{\mathrm{cut}}\) in that of \(m_3\). The wave theory behind the formulas is in the primer Equilibrium theory in 10 minutes.

The isotherm and the number that controls the distortion

The competitive Langmuir isotherm of a binary mixture is

\[ q_i = \frac{q_{\mathrm{s},i}\, b_i c_i}{1 + b_1 c_1 + b_2 c_2} , \]

with the Henry constants \(H_i = q_{\mathrm{s},i} b_i\), and component 1 eluting first (\(H_1 < H_2\)). On both operating parameter planes, \((s_{\mathrm{cut}}, s^{\mathrm{FF}})\) and \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\), the complete-separation region depends only on \(H_1\), \(H_2\) and the two dimensionless loadings \(b_1 c_1^{\mathrm{FF}}\) and \(b_2 c_2^{\mathrm{FF}}\), not on the saturation capacities as such. Two systems with the same Henry constants and the same \(b_i c_i^{\mathrm{FF}}\) have the same region (for purities below 100 % the ratio of the feed concentrations matters as well): for example \(q_{\mathrm{s}} = 5/5\), \(b = 0.30/0.50\) with \(c_1^{\mathrm{FF}} = 0.75\), \(c_2^{\mathrm{FF}} = 0.5\) gives exactly the region of the reference system below. When \(b_i c_i^{\mathrm{FF}} \to 0\), the isotherms become linear, \(q_i = H_i c_i\), and the region becomes the triangle.

The reference system on this page is the default of the tools: \(q_{\mathrm{s}} = 10/10\), \(b = 0.15/0.25\) (so \(H_1 = 1.5\), \(H_2 = 2.5\)), with the feed concentrations \(c_1^{\mathrm{FF}} = 1.5\) and \(c_2^{\mathrm{FF}} = 1\). To change the loading, the figures below scale this feed at the fixed ratio \(c_1^{\mathrm{FF}} : c_2^{\mathrm{FF}} = 1.5 : 1\).

The linear triangle

With linear isotherms the bands do not interact. Component \(i\) elutes for \(H_i - s^{\mathrm{FF}} \le s < H_i\), and one cut separates completely if

\[ H_1 \le s_{\mathrm{cut}} \le H_2 - s^{\mathrm{FF}} . \]

On the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) operating parameter plane, with \(S_{\mathrm{cut}} = s_{\mathrm{cut}} + s^{\mathrm{FF}}\), this is the triangle with the corners \(b = (H_1, H_1)\), \(a = (H_2, H_2)\) and the vertex \((H_1, H_2)\), reached at \(s^{\mathrm{FF}} = H_2 - H_1\) (1.0 for the reference system). In \(s_{\mathrm{cut}}\) the cut is defined from the end of the column feed, \(\Delta t^{\mathrm{F}}\); in batch elution \(\Delta t^{\mathrm{F}} = \Delta t^{\mathrm{FF}}\).

The Langmuir region and its four sides

With competitive Langmuir isotherms, the end of band 1 and the front of band 2 both move with the loading. The ideal chromatogram is known in closed form (Guiochon et al., 2006, Chapter 8; Siitonen and Sainio, 2011). Its features give the region directly. Let \(\omega_1^{\mathrm{F}} < \omega_2^{\mathrm{F}}\) be the two roots of the feed in the ω-transformation, that is of

\[ \frac{b_1 c_1^{\mathrm{FF}}\,\omega}{H_1 - \omega} + \frac{b_2 c_2^{\mathrm{FF}}\,\omega}{H_2 - \omega} = 1 . \]

A cut separates completely if it lies between the end of band 1 and the front of band 2. This gives four sides:

The straight form of the third side is the textbook's retention time of the second band with its plateau (Guiochon et al., 2006, Eqs. 8.61 and 8.62), simplified; the region computed on this site from the exact chromatograms agrees with it at every point.

The vertices \(w\) and \(r\)

The two straight sides cross at \(w\). There the end of band 1 meets the front of band 2: the bands touch. Setting the two bounds equal gives

\[ \begin{gathered} s^{\mathrm{FF}}_w = \frac{(H_2 - H_1)(H_2 - \omega_2^{\mathrm{F}})}{H_2\, b_2 c_2^{\mathrm{FF}}} , \\[4pt] s_{\mathrm{cut},w} = \frac{H_1\, \omega_2^{\mathrm{F}}}{H_2} . \end{gathered} \]

At \(r\) the plateau of component 2 has just eroded:

\[ \begin{gathered} s^{\mathrm{FF}}_r = \frac{(H_2 - \omega_2^{\mathrm{F}})^2}{H_2\, b_2 c_2^{\mathrm{FF}}} , \\[4pt] s_{\mathrm{cut},r} = \frac{(\omega_2^{\mathrm{F}})^2}{H_2} . \end{gathered} \]

On the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) plane, \(S_{\mathrm{cut}} = s_{\mathrm{cut}} + s^{\mathrm{FF}}\) becomes

\[ \begin{aligned} & S_{\mathrm{cut},w} = \frac{\omega_2^{\mathrm{F}}}{H_1 (H_2 - \omega_1^{\mathrm{F}})} \\ & \quad \times \left[\omega_1^{\mathrm{F}} (H_2 - H_1) + H_1 (H_1 - \omega_1^{\mathrm{F}})\right] , \end{aligned} \]

\[ \begin{aligned} & S_{\mathrm{cut},r} = \frac{\omega_2^{\mathrm{F}}}{H_1 (H_2 - \omega_1^{\mathrm{F}})} \\ & \quad \times \left[\omega_1^{\mathrm{F}} (H_2 - \omega_2^{\mathrm{F}}) + H_1 (\omega_2^{\mathrm{F}} - \omega_1^{\mathrm{F}})\right] . \end{aligned} \]

These are the vertex coordinates of Triangle Theory for the four-zone SMB, with \(\omega_1^{\mathrm{F}}\) and \(\omega_2^{\mathrm{F}}\) in the roles of its \(\omega_F\) and \(\omega_G\), as they must be, since the batch and SMB regions coincide. Here they follow from the band equations of the textbook (Guiochon et al., 2006, Eqs. 7.25a, 8.53, 8.55, 8.62 and 8.63). The straight side through \(w\) and \(r\), extended, meets the diagonal at \(f = (\omega_2^{\mathrm{F}}, \omega_2^{\mathrm{F}})\). The values of \(s^{\mathrm{FF}}\) at \(w\) and \(r\) are the touching-bands amount and the amount below which the plateau of component 2 erodes, the thresholds that the primer's hodograph shows.

Table 1. Feed roots and vertices of the complete-separation region of the reference system (\(H_1 = 1.5\), \(H_2 = 2.5\), \(b = 0.15/0.25\), \(c_1^{\mathrm{FF}} = 1.5\,c_2^{\mathrm{FF}}\)). Computed from the exact chromatograms (purity 1) and with the formulas above; the two agree to ten digits. In the linear limit \(r\) merges with \(a\).
\(c_1^{\mathrm{FF}}/c_2^{\mathrm{FF}}\)\(\omega_1^{\mathrm{F}}\)\(\omega_2^{\mathrm{F}}\) \(s_{\mathrm{cut},w}\)\(s^{\mathrm{FF}}_w\)\(S_{\mathrm{cut},w}\) \(s_{\mathrm{cut},r}\)\(s^{\mathrm{FF}}_r\)\(S_{\mathrm{cut},r}\)
→ 0 (linear)1.52.51.51.02.52.502.5
0.375/0.251.41352.37151.42290.82272.24552.24950.10572.3553
0.75/0.51.32632.28491.37090.68852.05942.08820.14812.2363
1.5/11.16482.18261.30960.50781.81741.90560.16112.0667
3/20.91802.09481.25690.32421.58101.75530.13141.8866

The regions at four feed concentrations

linear (\(c_i^{\mathrm{FF}} \to 0\))   \(c_2^{\mathrm{FF}} = 0.25\)   0.5   1   2   \(w\)   \(r\)

Figures 1 and 2. Complete-separation regions of the reference system for \(c_2^{\mathrm{FF}} = 0.25\), 0.5, 1 and 2, with \(c_1^{\mathrm{FF}} = 1.5\,c_2^{\mathrm{FF}}\) (darker for higher loading; \(c_2^{\mathrm{FF}} = 1\) shaded), computed from the exact solution of the ideal model, with the linear triangle dotted. Figure 1 is the \((s_{\mathrm{cut}}, s^{\mathrm{FF}})\) operating parameter plane, Figure 2 the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) plane. Circles mark \(w\), labelled with \(c_2^{\mathrm{FF}}\); triangles mark \(r\). As the loading rises, \(w\) moves down and to the left, below \(s_{\mathrm{cut}} = H_1 = 1.5\); the side from \(a\) to \(r\) curves; and each region leaves parts of the previous one behind instead of shrinking inside it. In Figure 2 the dashed line continues the side \(w\)–\(r\) of the \(c_2^{\mathrm{FF}} = 1\) region to \(f\) on the diagonal.

What the figures show:

Why the optimum moves to \(w\)

Under ideal conditions, \(w\) is the operating point with the most feed per cycle that still gives two pure products; with more feed the bands overlap. It is also the point of highest productivity with complete separation. Inside the region both products are collected pure and complete, so the productivity per volume pumped is \(c_i^{\mathrm{FF}} s^{\mathrm{FF}}/s_{\mathrm{cycle}}\), where \(s_{\mathrm{cycle}}\) is the cycle of stacked injections (Siitonen and Sainio, 2011, Eq. 34). For the reference system, the exact solution shows that this grows with \(s^{\mathrm{FF}}\) all the way up to \(w\). This matches the SMB: the touching-bands amount of a batch column equals the feed of the classical SMB at the vertex of its complete-separation region (Nicoud, 2015, as cited by Sainio, 2021).

Two effects of the competitive isotherm move the vertex:

The gap between the bands therefore closes at a smaller \(s^{\mathrm{FF}}\), so \(w\) moves down; and because band 1 now ends below \(H_1\), \(w\) also moves to the left.

What the nonlinearity costs for the reference feed, compared with linear isotherms with the same Henry constants (optimum at \(s^{\mathrm{FF}} = 1.0\), cut at 1.5):

The productivity basis is that of the design tool (see Notation); time-based productivity also needs the column and the flow rate.

The chromatogram at \(w\)

\(c_1\)   \(c_2\)   cut

Figure 3. Outlet profile of the reference system at \(s^{\mathrm{FF}} = s^{\mathrm{FF}}_w = 0.5078\), exact solution of the ideal model. Band 1 ends exactly where band 2 begins, at \(s = s_{\mathrm{cut},w} = 1.3096\), so a cut there gives two pure fractions with 100 % yield. Both pure plateaus are present: A at \(c_1 = 1.918\) and B at \(c_2 = 0.582\).

At \(w\) the bands touch (Figure 3). Band 1 starts with a shock at \(s = 0.657\) and a plateau at \(c_1 = 1.918\), above the feed concentration, because component 2 behind it concentrates component 1 (the displacement effect). Band 2 starts with a shock exactly at the end of band 1 and has a plateau at \(c_2 = 0.582\), below the feed concentration. There is no margin at all: more feed, a small error in the isotherm, or any dispersion makes the bands overlap. The page Limits of the ideal picture shows how much purity a real column loses at this operating point and how to back off from it.

Back to the Theory overview.

Further reading

  1. Siitonen, J., Sainio, T., Explicit equations for the height and position of the first component shock for binary mixtures with competitive Langmuir isotherms under ideal conditions, J. Chromatogr. A 1218 (2011) 6379–6387.
  2. Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.
  3. Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
  4. Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
  5. Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.
  6. Guiochon, G., Felinger, A., Shirazi, D.G., Katti, A.M., Fundamentals of Preparative and Nonlinear Chromatography, 2nd ed., Academic Press, Amsterdam (2006). ISBN 978-0-12-370537-2.
  7. Nicoud, R.-M., Chromatographic Processes: Modeling, Simulation and Design, Cambridge University Press, Cambridge, UK (2015).

Disclaimer: No liability is assumed for correctness or completeness of data generated with the tools available on this website.