Example 7: two SMB units or one multi-step unit?
A three-component split in simulated moving beds can be done with two classical four-zone units in series, or with one unit that alternates a feed step and a series of SMB switches, the Japan Organo (JO) process. Which needs less eluent and less adsorbent?
This example designs both for the system of Example 6, with linear isotherms under ideal conditions, and compares them on one stated basis. The process descriptions and the JO conditions are on the Ternary separations page; symbols are on the Notation page.
The system and the options
Henry constants \( H_1 = 1.0 \), \( H_2 = 1.8 \), \( H_3 = 3.0 \), the feed of Example 6, \( c^{\mathrm{FF}}_1 = 1.5 \) and \( c^{\mathrm{FF}}_2 = c^{\mathrm{FF}}_3 = 1 \), and the phase ratio \( F = (1-\varepsilon)/\varepsilon = 1.5 \) (\( \varepsilon = 0.4 \)), the value used in the figures of Sainio (2016). Four ways to get three pure products:
- Cascade, component 3 removed first. Unit 1 splits 1, 2 | 3; its raffinate 1 + 2 feeds unit 2, which splits 1 | 2. One column per zone in each unit, eight columns in all.
- Cascade, component 1 removed first. Unit 1 splits 1 | 2, 3; its extract 2 + 3 feeds unit 2, which splits 2 | 3. Also eight columns.
- Japan Organo, 2–2–2–2. Eight columns, two per zone, with \( N_{\mathrm{SMB}} = 8 \) SMB events in step 2, as in the paper.
- Batch elution with a centre cut, from Example 6, as a reference.
Designing each option
The cascades: two Triangle Theory designs
Each unit is a binary separation, and each is placed at the vertex of its triangle: zone II at the Henry constant of the less retained component of the key pair, zone III at that of the more retained one, zone I at the most retained component in the unit's feed and zone IV at the least retained one. The table gives the zone parameters and the liquid that crosses the unit boundary in one switch, per volume of stationary phase of one column of that unit.
| Unit | Split | \( s_{\mathrm{I}} \) | \( s_{\mathrm{II}} \) | \( s_{\mathrm{III}} \) | \( s_{\mathrm{IV}} \) | Feed | Eluent | Extract | Raffinate |
|---|---|---|---|---|---|---|---|---|---|
| Component 3 removed first | |||||||||
| 1 | 1, 2 | 3 | 3.0 | 1.8 | 3.0 | 1.0 | 1.2 | 2.0 | 1.2 (3) | 2.0 (1 + 2) |
| 2 | 1 | 2 | 1.8 | 1.0 | 1.8 | 1.0 | 0.8 | 0.8 | 0.8 (2) | 0.8 (1) |
| Component 1 removed first | |||||||||
| 1 | 1 | 2, 3 | 3.0 | 1.0 | 1.8 | 1.0 | 0.8 | 2.0 | 2.0 (2 + 3) | 0.8 (1) |
| 2 | 2 | 3 | 3.0 | 1.8 | 3.0 | 1.8 | 1.2 | 1.2 | 1.2 (3) | 1.2 (2) |
The stream that links the units is the weak point. With component 1 removed first, unit 1 takes 0.8 of fresh feed per switch but sends 2.0 of extract to unit 2, 2.5 times the volume of the feed it came from. With component 3 removed first the factor is \( 2.0/1.2 = 1.67 \). Unit 2 has to process all of it.
(a) Component 3 removed first
(b) Component 1 removed first
The Japan Organo unit
For the JO the separation of 1 and 2 happens in step 2 and the separation of 2 and 3 combines both steps. Figure 2 shows its regions on the same \( (s, S) \) operating parameter plane against those of the batch centre cut. The lower region does not start at \( H_1 \): component 2 must not reach the extract during step 2, which needs \( s_{\mathrm{JO2}} \ge 1.0952 \). It may pass the extract port at the last switch, because step 1 then carries it to its own outlet. The paper's Eq. (52) does not allow that and is more conservative, \( s_{\mathrm{JO2}} \ge 1.1833 \). The region is also cut from above by Eq. (53), which keeps component 2 out of the raffinate during the first SMB event. The largest feed sits where the two lines meet:
so one cycle takes \( s^{\mathrm{FF}} = 8 \times 0.3964 = 3.1714 \) volumes of fresh feed per volume of stationary phase of one column, or 0.3964 per volume of stationary phase in the whole unit. The batch column takes 0.8 per cycle, about twice as much. For the separation of 2 and 3, \( s_{\mathrm{JO3}} = H_2 = 1.8 \) gives the shortest feed step, with \( S_{\mathrm{JO3}} = 2.1964 \); then \( s^{(1)}_{\mathrm{I\text{–}II}} = 8\,(s_{\mathrm{JO3}} - s_{\mathrm{JO2}}) = 5.6381 \) in step 1.
Regeneration sets the eluent. The paper's limits, \( s_{\mathrm{JO1}} \ge H_3 \) (Eq. 50) and \( S_{\mathrm{JO4}} \le H_1 \) (Eq. 57), hold on the average of a cycle and are an approximation. An iterative scheme gives more accurate bounds: it follows the front of component 1 and the rear of component 3 through one cycle, event by event, and iterates to their positions at cyclic steady state (see Ternary separations). Here it gives \( s_{\mathrm{JO1}} \ge 3.0707 \) and \( S_{\mathrm{JO4}} \le 0.9368 \). This example uses \( s_{\mathrm{JO1}} = 3.071 \) and \( S_{\mathrm{JO4}} = 0.936 \): in step 2, \( s^{(2)}_{\mathrm{I}} = 2.3662 \), \( s^{(2)}_{\mathrm{II\text{–}III}} = 1.0952 \) and \( s^{(2)}_{\mathrm{IV}} = 0.5396 \). The eluent consumption below is 6.8 % higher than with the paper's limits.
A check by simulation
For this page the cyclic steady state of every option was also simulated exactly with the ideal model: packets of each component move through the zones at their own speed, split at the ports in proportion to the flows, and move back one column at every switch. Just inside every boundary above, including the bound on \( s_{\mathrm{JO2}} \) and the regeneration bounds of the iterative scheme, all products came out pure; just outside, the product that the boundary protects was contaminated. At the paper's regeneration limits, Eqs. (50) and (57), component 1 still reached the extract and the intermediate, and component 3 the raffinate and the intermediate.
A common basis for the comparison
Under ideal conditions any flow rate gives the same purities, so the regions alone cannot say how much adsorbent a process needs: a cycle can be made as short as one likes. A comparison has to fix a time scale. The usual limit in practice is the pressure drop, so this example fixes the largest liquid velocity.
Assumptions of this example (not from the paper)
- Every column of every unit has the same packing and the same length \( L \). No liquid velocity may exceed \( u_{\max} \), and each unit runs its fastest zone at \( u_{\max} \). The time unit is \( t_0^* = L/u_{\max} \), the dead time of one column at that velocity.
- Every unit works at the vertex of its region (no safety margin), with zones I and IV at the regeneration limits found above.
- The cascade units are coupled directly, without a buffer tank or solvent removal. The columns of unit 2 are sized so that it takes the whole product stream of unit 1 at its own vertex.
Two measures follow, both per volume of fresh feed:
- Eluent use \( E \): fresh eluent volume per fresh feed volume. It does not depend on the flow rates at all.
- Adsorbent need \( A = V_{\mathrm{s,total}}/(\bar Q^{\mathrm{FF}} t_0^*) \): the stationary-phase volume of all columns per mean fresh-feed flow, in units of \( t_0^* \). Smaller is better; at a given feed rate the adsorbent scales with \( A \).
The cycle times follow from the definitions of the \( s \) parameters. A four-zone unit switches every \( \Delta t_{\mathrm{switch}} = t_0^*(1 + F s_{\mathrm{I}}) \), because zone I carries the largest flow (Eq. 6 of the paper). A JO cycle lasts \( F t_0^* s^{(1)}_{\mathrm{I\text{–}II}} \) for step 1 plus \( t_0^*(1 + F s^{(2)}_{\mathrm{I}}) \) for each SMB event, which adds up to \( N_{\mathrm{SMB}}\, t_0^* (1 + F s_{\mathrm{JO1}}) \). A batch cycle of stacked injections lasts \( F t_0^* s_{\mathrm{cycle}} \).
Results
| Option | Columns | Fresh feed per cycle | Eluent use \( E \) | Adsorbent need \( A \) | \( E \) per amount of product | \( A \) per amount of product |
|---|---|---|---|---|---|---|
| Cascade, 3 removed first | 8 | – | 3.33 | 49.2 | 0.952 | 14.0 |
| Cascade, 1 removed first | 8 | – | 5.00 | 73.3 | 1.43 | 21.0 |
| Japan Organo 2–2–2–2 | 8 | 0.396 | 5.39 | 113.1 | 1.54 | 32.3 |
| Batch, centre cut (reference) | 1 | 0.8 | 2.50 | 5.25 | 0.714 | 1.50 |
What the numbers say
The feed concentrations. With linear isotherms nothing in the designs depends on them, so \( E \) and \( A \) per volume of fresh feed are the same as for an equal feed. Per amount of product, every option gains in the same proportion from the richer feed (3.5 instead of 3 per volume of feed), because each recovers all three products. The ranking does not change.
Order of the cascade. Under these assumptions a cascade needs \( E = 2\,(H_3 - H_1)/\Delta H_{\mathrm{first}} \), where \( \Delta H_{\mathrm{first}} \) is the difference of Henry constants across the first split: unit 1 must regenerate over the whole range \( H_3 - H_1 \), and its product stream, diluted by the same factor, costs unit 2 as much eluent again. Splitting the easier pair first (here 2/3, with \( \Delta H = 1.2 \) against 0.8) lets unit 1 take more feed per switch and dilutes the link less. It saves about a third of the eluent (3.33 against 5.00) and of the adsorbent (49.2 against 73.3).
JO against the cascades. With the same eight columns, the JO takes only 0.396 of fresh feed per cycle per volume of stationary phase, because the two columns of zone II and of zone III limit how hard step 2 can push component 2 (the bound on \( s_{\mathrm{JO2}} \) and Eq. 53). Its cycle of \( 8 \times t_0^*(1 + 1.5 \times 3.071) \), with the regeneration limit of the iterative scheme, is long for that feed. It needs about 2.3 times the adsorbent and 1.6 times the eluent of the better cascade. What it offers in return, one unit instead of two and no stream between units, lies outside the ideal model.
Batch. The batch column looks best on both counts, and the reason is instructive rather than a recommendation. With stacked injections it runs its single column at full velocity all the time, with bands of consecutive injections side by side, while every SMB option keeps zones at lower flows and spends adsorbent on regeneration. Its \( A \) also depends directly on the column length chosen for it: here it is one column of length \( L \). If it had to be as long as the eight SMB columns together, as in the paper's own simulations, its \( A \) would be eight times larger, 42.0, still the smallest. What the ideal model cannot see is efficiency: in SMB-type operation the dispersed fronts are kept inside the unit, which raises the effective number of plates (the paper finds this for the JO in its simulations), while a batch column needs all its plates in one bed (see Limits of the ideal picture). The paper itself warns that productivities of different processes cannot be compared under ideal conditions without such constraints, and that the fair benchmark for the JO is a cross-flow SMB with the same number of columns.
What this example shows
- A cascade of two four-zone units is two Triangle Theory designs; split the pair with the larger difference of Henry constants first.
- The JO with two columns per zone is limited by its column arrangement, not by the isotherms, and processes less than half the feed per cycle of the batch region.
- Eluent use is independent of flow rates; adsorbent need is not, and every comparison of it rests on an assumed time basis.
Theory: ternary separations · Example 6: centre cut · Notation · All examples
Further reading
- Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
- Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.
- Kessler, L.-C., Seidel-Morgenstern, A., Theoretical study of multicomponent continuous countercurrent chromatography based on connected 4-zone units, J. Chromatogr. A 1126 (2006) 323–337.
- Mata, V., Rodrigues, A., Separation of ternary mixtures by pseudo-simulated moving bed chromatography, J. Chromatogr. A 939 (2001) 23–40.
- Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.