Skip to the content
Unified Design Method Design of chromatographic separation processes

Event algebra

Batch elution, steady-state recycling and simulated moving beds look like different processes, but all of them are sequences of timed events. The Unified Design method describes three kinds of events with compatible dimensionless parameters and a few rules for combining them. With these rules the operating parameters of a new process variant can be written down in a few lines, its feasible region drawn on the same operating parameter plane as all the others, and a design transferred from one process to another.

Symbols and “ideal conditions”: Notation and definitions. This page follows Sainio (2016), Section 2, and Sainio (2021), Section 2.1. Back to the Theory overview.

Three kinds of events

Fixed-bed eventA column through which liquid flows at the flow rate Q for the time delta t; the volume pumped per stationary-phase volume is s_FB.Fixed-bed event (FB)liquid inoutflow Q for a time Δtvolume pumped QΔt, per stationary-phase volume: sFBfeeding, eluting, withdrawing
Cut eventThe column outlet is switched by a valve from one collection vessel to the next at the instant t_cut; the cut event has no duration.Cut event (cut)nn + 1valveswitch the outlet at the instant tcut:no duration, outside the column: scutproduct, waste or recycle fractions
Simulated moving-bed eventLiquid flows through a train of columns for the switch time; then every column moves one position against the direction of flow.SMB event (SMB)position 1position 2position 3liquid flows for Δtswitch, thenevery column moves one positionagainst the flow: sSMBzones of SMB, I-SMB, Japan Organo

Figure 1. The three kinds of timed events. A fixed-bed event moves liquid into, through or out of a column for a while; a cut event switches the outlet from one fraction to the next at an instant; an SMB event is a fixed-bed event that ends with every column moving one position against the flow.

Each event gets a dimensionless parameter: the volume of liquid that flows during the event, divided by the volume of stationary phase in one column, \((1-\varepsilon)V_\mathrm{col}\). With \(F = (1-\varepsilon)/\varepsilon\) and \(t_0 = \varepsilon V_\mathrm{col}/Q\) (Sainio 2016, Eqs. 5 to 7):

\[ s_{\mathrm{FB}} = \frac{Q\,\Delta t}{(1-\varepsilon)V_\mathrm{col}} = \frac{\Delta t}{t_0}F^{-1}, \qquad s_{\mathrm{SMB}} = \frac{Q\,\Delta t_\mathrm{switch} - \varepsilon V_\mathrm{col}}{(1-\varepsilon)V_\mathrm{col}} = \left(\frac{\Delta t_\mathrm{switch}}{t_0} - 1\right)F^{-1}, \]
\[ s_{\mathrm{cut}} = \frac{Q\,\left(t_\mathrm{cut} - \Delta t^{\mathrm{F}}\right) - \varepsilon V_\mathrm{col}}{(1-\varepsilon)V_\mathrm{col}} = \left(\frac{t_\mathrm{cut} - \Delta t^{\mathrm{F}}}{t_0} - 1\right)F^{-1}. \]

The fresh feed is an FB event too: \(s^{\mathrm{FF}} = Q^{\mathrm{FF}}\Delta t^{\mathrm{FF}}/\left((1-\varepsilon)V_\mathrm{col}\right)\). Here \(\Delta t^{\mathrm{F}}\) is the duration of the column feed, which may contain recycled material, and \(\Delta t^{\mathrm{FF}}\) that of the fresh feed; in batch elution they are equal.

Scaling and alignment

All three parameters scale in the same way: one unit of \(s\) is always one stationary-phase volume of liquid (Sainio 2016, Eq. 1). Their zeros are aligned so that \(s = 0\) means the same thing for each event: an FB event of zero duration, an SMB event whose switch time equals the dead time (a non-adsorbing species does not move relative to the ports), and a cut at the moment when the rear of a non-adsorbing tracer of the column feed leaves the column, \(t_\mathrm{cut} = \Delta t^{\mathrm{F}} + t_0\) (Sainio 2016, Eqs. 2 to 4). Measuring cuts from the end of the feed, rather than from its start, makes the elution of the rear of component \(j\) independent of the feed amount: it is at \(s_{\mathrm{cut}} = H_j\) for linear isotherms.

Alignment of the time axis, the cumulative FB parameter and s_cutOne batch cycle with feed from 0 to delta t F and eluent after it. The tracer leaves the column between t0 and delta t F plus t0. The cumulative fixed-bed parameter starts at 0, equals s F at the end of the feed; s_cut is zero when the rear of the tracer leaves. A component j with H_j = 1.5 leaves between s_cut = H_j minus s F and H_j.inletfeedeluentoutlettracerjt0ΔtFt0ΔtF + t0ŝFB0sFsF + F-1scut−0.500.511.52Hj − sFHj

Figure 2. One batch cycle drawn to scale for \(F = 2/3\) and a column feed of \(s^{\mathrm{F}} = 0.75\) (so \(\Delta t^{\mathrm{F}} = 0.5\,t_0\)). The cumulative FB parameter \(\hat{s}_{\mathrm{FB}}\) counts the liquid pumped since the start of the cycle; \(s_{\mathrm{cut}}\) has the same unit and is zero when the rear of the tracer leaves the column. A component with \(H_j = 1.5\) leaves between \(s_{\mathrm{cut}} = H_j - s^{\mathrm{F}} = 0.75\) and \(H_j = 1.5\), that is between \(2.0\,t_0\) and \(2.5\,t_0\).

The rules

The rules below follow from the definitions and are stated in Sainio (2016, Section 2 and Appendix A) and Sainio (2021, Section 2.1). R6 is the result for linear isotherms under ideal conditions; R1 to R5 hold for any isotherm and also under non-ideal conditions, because they are statements about volumes of liquid.

R1 Consecutive FB events add up
FB events performed one after the other in the same column are one FB event, \(\hat{s}_{\mathrm{FB}} = \sum_h s_{\mathrm{FB}}^{(h)}\).
R2 A cut is read off the FB sum
A cut made when the cumulative FB parameter has reached \(\hat{s}_{\mathrm{FB}}\) has \(s_{\mathrm{cut}} = \hat{s}_{\mathrm{FB}} - s^{\mathrm{F}} - F^{-1}\) (Sainio 2016, Eq. 11). The offset \(F^{-1}\) is the liquid volume of the column, \(\varepsilon V_\mathrm{col}\), in stationary-phase units.
R3 Two cuts make an FB event
A cut has no duration, so it cannot be turned into an FB event, but the difference of two cuts can: \(s_{\mathrm{cut},b} - s_{\mathrm{cut},a}\) is the liquid collected between them. Every fraction, whether product, waste or recycle, is an FB event of this size.
R4 SMB events absorb FB events
An SMB event followed by an FB event, or done at the same time as one, is a single SMB event; an SMB event can be split into FB events followed by a shorter SMB event; and the difference of two SMB events is one or more FB events.
R5 Nodes balance the streams
Where streams enter or leave a multicolumn unit between two zones, the external stream is the difference of the adjacent zones' parameters, for example \(s^{\mathrm{FF}} = s_\mathrm{III} - s_\mathrm{II}\) at the feed node (Sainio 2016, Eq. 12).
R6 Fronts move by known distances
With linear isotherms under ideal conditions, a concentration front of component \(j\) moves the distance \(l_{\mathrm{FB},j} = s_{\mathrm{FB}}/\bar{H}_j\) during an FB event and \(l_{\mathrm{SMB},j} = (s_{\mathrm{SMB}} - H_j)/\bar{H}_j\) during an SMB event, in column lengths, with \(\bar{H}_j = F^{-1} + H_j\) (Sainio 2016, Eqs. 15 and 16). Complete separation is a set of sign conditions on these distances.

The auxiliary parameter \(S\) puts the fresh feed into every operating point, so that the feasible regions can be drawn like those of Triangle Theory: \(S = s + s^{\mathrm{FF}}\) for processes made of FB and cut events, and \(S = s + s^{\mathrm{FF}}/N_\mathrm{SMB}\) when the repeating sequence contains \(N_\mathrm{SMB}\) SMB events (Sainio 2016, Eqs. 8 and 9). The design itself needs only the \(s\)-parameters.

Two cut events define a fixed-bed eventAn outlet profile with two cut events a and b; the liquid collected between them is a fixed-bed event of size s_cut,b minus s_cut,a.Two cuts make an FB eventscutscut,ascut,bFBliquid collected in between: sFB = scut,b − scut,a
An SMB event equals FB events followed by a shorter SMB eventA bar for one SMB event equals a sequence of two fixed-bed events and a shorter SMB event; the column shift happens only at the end.An SMB event split into FB eventsSMB event: sSMB=sFB(1)sFB(2)sSMB'sSMB = sFB(1) + sFB(2) + sSMB'

Figure 3. Left, rule R3: the liquid collected between two cuts is an FB event. Right, rule R4: an SMB event equals FB events followed by a shorter SMB event; only the last part ends with the column shift (after Sainio 2016, Fig. 1).

Worked compositions

All examples use linear isotherms, \(H_1 = 1.5\) and \(H_2 = 2.5\), so that every step can be checked by hand. The same events and rules apply to nonlinear isotherms; only the positions of the fronts then have to come from the ideal-model solution instead of R6.

Batch elution

Batch elution: FB (feed) + FB (elution) + cutsBatch elution with s^FF = 0.8: the feed is one FB event; the bands of components 1 and 2 leave between H_i minus 0.8 and H_i; one cut at 1.6 splits the effluent into two pure products.Batch elution: FB (feed) + FB (elution) + cutsinletfresh feedeluentFB event sF = 0.8product 1product 2scut00.511.522.5outletscut

Events: an FB event of fresh feed, \(s^{\mathrm{F}} = s^{\mathrm{FF}}\), an FB event of eluent, and cut events. The front of component \(j\) has moved \(l = s^{\mathrm{FF}}/\bar{H}_j\) when the feed ends (R6) and leaves the column when the eluent has added the rest, \(\bar{H}_j - s^{\mathrm{FF}}\); the sum is \(\hat{s}_{\mathrm{FB}} = \bar{H}_j\) (R1), and R2 gives \(s_{\mathrm{cut}} = H_j - s^{\mathrm{FF}}\). The rear starts when the feed ends and needs \(\bar{H}_j\), so \(\hat{s}_{\mathrm{FB}} = s^{\mathrm{FF}} + \bar{H}_j\) and \(s_{\mathrm{cut}} = H_j\) (Sainio 2016, Appendix A). A cut at \(s_{\mathrm{cut}}\) between the bands gives two pure products if \(H_1 \le s_{\mathrm{cut}}\) and \(s_{\mathrm{cut}} + s^{\mathrm{FF}} = S_{\mathrm{cut}} \le H_2\): the complete-separation triangle. In the figure \(s^{\mathrm{FF}} = 0.8\) and the cut is at 1.6, the operating point \((1.6, 2.4)\).

Batch with a waste fraction

Batch with a waste fraction: two cuts, waste = FB eventBatch with a waste fraction (Example 3, s^FF = 1.4): the bands overlap from 1.1 to 1.5; cuts at 1.1 and 1.5 send the overlap to waste, an FB event of size 0.4.Batch with a waste fraction: two cuts, waste = FB eventinletfresh feedeluentFB event sF = 1.4product 1wasteproduct 2scut00.511.522.5outletsW = scut3 − scut2 = 0.4scut2scut3

Add one cut: product 1 ends at \(s_{\mathrm{cut}2}\), product 2 starts at \(s_{\mathrm{cut}3}\), and by R3 the waste is the FB event \(s^{\mathrm{W}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2}\). The process now has two operating points at the same distance \(s^{\mathrm{FF}}\) from the diagonal. Pure products need \(S_{\mathrm{cut}2} \le H_2\) (product 1 ends before component 2 arrives) and \(s_{\mathrm{cut}3} \ge H_1\) (product 2 starts after component 1 has left) (Sainio 2021, Eqs. 35 to 37). In the figure (Example 3) \(s^{\mathrm{FF}} = 1.4\), and the points are \((1.1, 2.5)\) and \((1.5, 2.9)\).

Mixed-recycle steady-state recycling

Mixed-recycle SSR: the recycle fraction feeds the next cycleMixed-recycle SSR (Example 8, run B): the column feed of 1.4 is the recycle fraction of the previous cycle mixed with 1.0 of fresh feed; cuts at 1.1 and 1.5 send the middle to the tank.Mixed-recycle SSR: the recycle fraction feeds the next cycleinletrecycle + fresh feed, mixedeluentFB event sF = 1.4 (sFF = 1, sR = 0.4)product 1recycleproduct 2scut00.511.522.5outletto the tank: sR = scut3 − scut2scut2scut3

Send the middle fraction to a tank instead of the drain and mix it with the next fresh feed. R3 is used twice: the recycle fraction leaves as the FB event \(s^{\mathrm{R}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2}\) and comes back as part of the column feed, \(s^{\mathrm{F}} = s^{\mathrm{FF}} + s^{\mathrm{R}}\). Cuts are measured from the end of the column feed, so the front of component 2 is now at \(H_2 - s^{\mathrm{F}}\), and product 1 is pure if \(s_{\mathrm{cut}2} + s^{\mathrm{F}} \le H_2\). Inserting the closure gives \(s_{\mathrm{cut}2} + s^{\mathrm{FF}} + s_{\mathrm{cut}3} - s_{\mathrm{cut}2} = S_{\mathrm{cut}3} \le H_2\). Together with \(s_{\mathrm{cut}3} \ge H_1\), both conditions now concern the cut-3 point, which must lie in the triangle. R2 also gives the cycle: with a single tank the next column feed can be made up only after cut 3, when \(\hat{s}_{\mathrm{FB}} = s_{\mathrm{cut}3} + s^{\mathrm{F}} + F^{-1}\). Waste and recycle fractions takes this further, and Example 8 computes it. The figure shows Example 8, run B: \(s^{\mathrm{FF}} = 1.0\), cuts at 1.1 and 1.5, column feed 1.4.

Four-zone SMB

Four-zone SMB: SMB events in every zoneFour columns, one per zone, connected in a loop. Eluent enters before zone I, extract leaves between zones I and II, feed enters between zones II and III, raffinate leaves between zones III and IV, and the liquid from zone IV is recycled to zone I. After every switch time the columns move one position against the flow.Four-zone SMB: SMB events in every zonezone IsIzone IIsIIzone IIIsIIIzone IVsIVrecycle (zone IV to zone I)eluentextractfeedraffinateshift afterΔtswitch

Every zone performs one SMB event per switch, \(N_\mathrm{SMB} = 1\). The nodes give the external streams (R5): fresh feed \(s^{\mathrm{FF}} = s_\mathrm{III} - s_\mathrm{II}\), eluent \(s_\mathrm{I} - s_\mathrm{IV}\), extract \(s_\mathrm{I} - s_\mathrm{II}\) and raffinate \(s_\mathrm{III} - s_\mathrm{IV}\). Component 1 must move towards the raffinate in zone II and component 2 towards the extract in zone III: \(l_{1,\mathrm{II}} \ge 0 \Leftrightarrow s_\mathrm{II} \ge H_1\) and \(l_{2,\mathrm{III}} \le 0 \Leftrightarrow s_\mathrm{III} \le H_2\) (R6; Sainio 2016, Eqs. 25 and 26). With \(S_\mathrm{II} = s_\mathrm{II} + s^{\mathrm{FF}} = s_\mathrm{III}\) this is the batch triangle on the \((s_\mathrm{II}, S_\mathrm{II})\) operating parameter plane, the \((m_2, m_3)\) plane of Triangle Theory (Storti et al., 1993). Zones I and IV regenerate the adsorbent and the eluent if \(s_\mathrm{I} \ge H_2\) and \(s_\mathrm{IV} \le H_1\). The same operating point \((1.6, 2.4)\) as in the batch example gives the same purities under ideal conditions.

Variants

The same few rules give the parameters of less common schemes. An SMB with a waste outlet has the closure \(s^{\mathrm{FF}} - s^{\mathrm{W}} = s_\mathrm{III} - s_\mathrm{II}\); with \(s_3 = s_\mathrm{II} - s^{\mathrm{W}}\) the zone III parameter becomes \(S_3 = s_\mathrm{III}\), and a five-zone unit with the waste outlet between feed and raffinate reproduces batch with a waste fraction (Sainio 2021, Eqs. 38 to 42). Processes with several SMB events per cycle, such as the Japan Organo process or intermittent SMB with more than one switch per step, combine FB events and \(N_\mathrm{SMB} > 1\) SMB events into new parameters such as \(s_\mathrm{JO3} = s_\mathrm{I-II}^{(1)}/N_\mathrm{SMB} + s_\mathrm{II-III}^{(2)}\) (Sainio 2016, Sections 4 and 5); see Ternary separations.

One operating parameter plane for all of them

Operating points of four processes on the same (s, S) operating parameter planeThe complete-separation triangle with corners (1.5, 1.5), (1.5, 2.5) and (2.5, 2.5). Batch and SMB share the operating point (1.6, 2.4). Example 3, batch with waste, has its cut-2 point at (1.1, 2.5) on the horizontal extension and its cut-3 point at (1.5, 2.9) on the vertical extension of the triangle. SSR run B has its cut-3 point at the vertex (1.5, 2.5) and its cut-2 point at (1.1, 2.1).1.01.51.52.02.02.52.53.0sSbatch (scut, Scut)= SMB (sII, SII)Example 3, cut 2Example 3, cut 3Example 8 (SSR, run B), cut 3run B, cut 2complete separation

Figure 4. The worked compositions on the same \((s, S)\) operating parameter plane. Batch elution and four-zone SMB share the operating point (1.6, 2.4) inside the triangle. Example 3 (batch with waste) has its cut-2 point on the horizontal extension \(S = H_2\) and its cut-3 point on the vertical extension \(s = H_1\). Example 8, run B (SSR) has its cut-3 point at the vertex and its cut-2 point 0.4 to the left.

Summary: events, operating points and the conditions for two pure products with linear isotherms under ideal conditions.
ProcessEvents per cycleOperating point(s)Two pure products
Batch elutionFB feed, FB elution, cuts\((s_{\mathrm{cut}}, S_{\mathrm{cut}})\)\(H_1 \le s_{\mathrm{cut}} \le S_{\mathrm{cut}} \le H_2\)
Batch with wasteas batch, two cuts; \(s^{\mathrm{W}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2}\)\((s_{\mathrm{cut}2}, S_{\mathrm{cut}2})\), \((s_{\mathrm{cut}3}, S_{\mathrm{cut}3})\)\(S_{\mathrm{cut}2} \le H_2\), \(s_{\mathrm{cut}3} \ge H_1\)
Mixed-recycle SSRFB column feed \(s^{\mathrm{FF}} + s^{\mathrm{R}}\), FB elution, two cuts; \(s^{\mathrm{R}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2}\)\((s_{\mathrm{cut}3}, S_{\mathrm{cut}3})\)\(H_1 \le s_{\mathrm{cut}3} \le S_{\mathrm{cut}3} \le H_2\)
Four-zone SMBone SMB event per zone; nodes by R5\((s_\mathrm{II}, S_\mathrm{II} = s_\mathrm{III})\)\(H_1 \le s_\mathrm{II} \le S_\mathrm{II} \le H_2\), plus \(s_\mathrm{I} \ge H_2\), \(s_\mathrm{IV} \le H_1\)

Three of the four processes share one triangle, and the fourth reaches beyond it only by discarding feed. This is the sense of “unified”: the feasible regions coincide, so under ideal conditions an operating point found for one process is an operating point of the others. With real columns, dispersion affects each process differently, and the transfer becomes approximate (Limits of the ideal picture). Turning the dimensionless operating point into flow rates and times is described in From dimensionless parameters to equipment.

Further reading

  1. Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
  2. Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
  3. Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.
  4. Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.

Disclaimer: No liability is assumed for correctness or completeness of data generated with the tools available on this website.