Notation and definitions
The same symbol means the same thing on every page of this site. The boxes below define the terms that the tools depend on; the table at the end lists every symbol with its unit.
Why it matters: the UD regions are exact under ideal conditions, but only for the inputs they were computed for. A porosity on one basis and a Henry constant on another, or a purity counted in a different way, give a shifted region without any warning. Components are numbered in elution order: component 1 is the less retained one, \( H_1 < H_2 < H_3 \).
Ideal conditions
Ideal conditions means the ideal model of chromatography, solved with equilibrium theory (Guiochon et al., 2006, Chapter 7; Sainio, 2021, Section 2.2):
- the two phases are in equilibrium at every point: no mass-transfer resistance and no adsorption kinetics;
- no axial dispersion: the column efficiency is infinite;
- isocratic and isothermal operation: the isotherm is the same everywhere and at all times;
- constant flow rate, incompressible phases, no radial concentration gradients;
- the column is initially clean, and the adsorbent is fully regenerated between cycles (in SMB, by zones I and IV).
Under these conditions every result on this site is exact: profiles, regions, purities and yields follow from the isotherm and the feed alone. In practice the column efficiency is finite. Fronts are smoothed, the regions shrink, and a design transferred from one process to another is approximate. The Limits of the ideal picture page shows by how much.
Porosity, dead time, phase ratio and the basis of \( q \)
The model behind every page is the mass balance of the ideal model (Guiochon et al., 2006, Eq. 7.1; Siitonen and Sainio, 2011, Eq. 1)
\[ \frac{\partial}{\partial t}\left(c_i + F q_i\right) + u\,\frac{\partial c_i}{\partial z} = 0 \]The quantities in it are defined as follows.
- Total porosity \( \varepsilon \)
- The volume of liquid in the column that the solutes can reach, between and inside the particles, per column volume. For porous particles \( \varepsilon = \varepsilon_{\mathrm{e}} + (1-\varepsilon_{\mathrm{e}})\,\varepsilon_{\mathrm{p}} \), with \( \varepsilon_{\mathrm{e}} \) the external (interparticle) porosity and \( \varepsilon_{\mathrm{p}} \) the particle porosity. This is the porosity of the textbook (Guiochon et al., 2006, Section 7.1). The UD papers call \( \varepsilon \) the bed porosity; with porous particles their equations hold as written when \( \varepsilon \) is the total porosity and \( t_0 \) the dead time of a tracer that enters the pores, as here.
- Dead time \( t_0 \)
- \( t_0 = \varepsilon V_{\mathrm{col}}/Q = L/u \): the elution time of a small, non-adsorbing tracer that enters the pores, at the flow rate \( Q \). \( u = Q/(\varepsilon A) \) is the interstitial velocity of the liquid.
- Phase ratio \( F \)
- \( F = (1-\varepsilon)/\varepsilon \): volume of stationary phase per volume of liquid. (The superscripts \( ^{\mathrm{F}} \) and \( ^{\mathrm{FF}} \) are labels for the column feed and the fresh feed, not the phase ratio.)
- Basis of \( q \)
- \( q_i \) is the amount of component \( i \) in the stationary phase per volume of stationary phase, \( (1-\varepsilon)V_{\mathrm{col}} \): the solid skeleton of the particles, without their pore liquid. It has the unit of \( c \), for example g/L.
- Henry constant \( H_i \)
- The initial slope of the isotherm, \( H_i = \lim_{c\to 0} \partial q_i/\partial c_i \), dimensionless. Linear isotherm: \( q_i = H_i c_i \). Competitive Langmuir isotherm: \( q_i = q_{\mathrm{s},i} b_i c_i / (1 + b_1 c_1 + b_2 c_2) \), so \( H_i = q_{\mathrm{s},i}\, b_i \). Under ideal conditions a small pulse elutes at \( t_{\mathrm{R},i} = t_0 (1 + F H_i) \), so a Henry constant found from retention times is \( H_i = (t_{\mathrm{R},i}/t_0 - 1)/F \).
Porous particles: keep \( \varepsilon \), \( t_0 \) and \( H \) on one basis
Some authors use the external porosity \( \varepsilon_{\mathrm{e}} \) instead, with \( t_{0,\mathrm{e}} = \varepsilon_{\mathrm{e}} V_{\mathrm{col}}/Q \) (a tracer that cannot enter the pores) and the concentration in the stationary phase counted per particle volume, pore liquid included. That set is also consistent. Its Henry constants are \( H_{\mathrm{e},i} = \varepsilon_{\mathrm{p}} + (1-\varepsilon_{\mathrm{p}})H_i \), and it predicts the same retention times. But its \( s \) axis is another one, \( s_{\mathrm{e}} = \varepsilon_{\mathrm{p}} + (1-\varepsilon_{\mathrm{p}})\,s \), and its fresh feed is \( s^{\mathrm{FF}}_{\mathrm{e}} = (1-\varepsilon_{\mathrm{p}})\,s^{\mathrm{FF}} \). (Derivation: write both mass balances with \( \varepsilon = \varepsilon_{\mathrm{e}} + (1-\varepsilon_{\mathrm{e}})\varepsilon_{\mathrm{p}} \) and compare the terms.)
So do not mix the two sets. Take \( \varepsilon \), \( t_0 \) and \( H \) from one basis, and if you find \( H \) from retention times, use the same \( \varepsilon \) and \( t_0 \) as in the tool. For example, with \( \varepsilon_{\mathrm{e}} = 0.4 \) and \( \varepsilon_{\mathrm{p}} = 0.5 \) (\( \varepsilon = 0.7 \)) and \( H = 1.5 \) and 2.5, the largest feed for complete separation is \( \Delta t^{\mathrm{FF}} = 0.3\,V_{\mathrm{col}}/Q \) in either consistent set. Particle-basis Henry constants with the total porosity give \( 0.15\,V_{\mathrm{col}}/Q \), half of it; total-basis Henry constants with the external porosity give \( 0.6\,V_{\mathrm{col}}/Q \), twice it, and the bands overlap.
With a Langmuir isotherm, use the total porosity. On the particle basis the pore liquid adds a linear term \( \varepsilon_{\mathrm{p}} c \) to the isotherm, and it is no longer of Langmuir form.
Purity and yield
With one cut, the effluent of a binary separation is split into two product fractions: the first fraction is the product of component 1 and the last fraction that of component 2. With two cuts, the middle fraction is waste (or recycle). In each product fraction, with \( n_i \) the amount of component \( i \) collected in it per cycle (Siitonen and Sainio, 2011, Eqs. 29–31):
\[ \mathit{Pu}_i = \frac{n_i}{n_1 + n_2}, \qquad Y_i = \frac{n_i}{n_i^{\mathrm{FF}}} \]The purity \( \mathit{Pu}_i \) is the share of component \( i \) among the solutes of its product fraction (the eluent does not count). The yield \( Y_i \) is the part of the injected amount \( n_i^{\mathrm{FF}} \) that reaches the product fraction. A purity target \( \mathit{Pu}_{i,\min} \) is meaningful only above the feed purity \( \mathit{Pu}_i^{\mathrm{FF}} = c_i^{\mathrm{FF}}/(c_1^{\mathrm{FF}} + c_2^{\mathrm{FF}}) \), which any cut reaches; the tools reject targets at or below it.
On the \( s \) axis the amounts are areas under the outlet profile, \( n_i' = \int c_i\,\mathrm{d}s \), per volume of stationary phase. The injected amount is \( c_i^{\mathrm{FF}} s^{\mathrm{FF}} \). Purity and yield do not depend on the porosity, the dead time or the flow rate.
Productivity and eluent consumption
Batch elution is assumed to run with stacked injections: the first band of an injection starts to elute just as the last band of the previous one has left the column, so consecutive cycles touch but do not overlap (Siitonen and Sainio, 2011, Eq. 34). On the \( s \) axis the cycle runs from the front of the first band to the end of the last band,
\[ s_{\mathrm{cycle}} = s_{\mathrm{end},2} - s_{\mathrm{front},1} \]In time the cycle lasts \( t_{\mathrm{cycle}} = s_{\mathrm{cycle}}\, t_0 F \), and \( s_{\mathrm{cycle}} \) is also the volume pumped per cycle (feed and eluent) per volume of stationary phase. With \( m_i = \int c_i\,\mathrm{d}s \) over the product fraction, the amount of product per cycle per volume of stationary phase:
- Productivity per volume pumped, \( \mathit{PR}_i = m_i/s_{\mathrm{cycle}} \): product per volume of liquid pumped through the column (Siitonen and Sainio, 2011, Eq. 32 on the \( s \) axis). Unit of \( c \), for example g per L pumped.
- Eluent consumption, \( \mathit{EC}_i = (s_{\mathrm{cycle}} - s^{\mathrm{FF}})/m_i \): eluent per amount of product (Eq. 33). Inverse unit of \( c \), for example L per g.
Both are independent of the flow rate, the porosity and the dead time. Under ideal conditions any flow rate gives the same profile on the \( s \) axis, and pressure drop is not modelled, so a productivity per time needs your flow rate, given through \( t_0 \) and \( \varepsilon \):
\[ \mathit{PR}^{t}_i = \frac{m_i}{s_{\mathrm{cycle}}\, t_0 F} \]per volume of stationary phase, and per column volume
\[ \mathit{PR}^{t}_{i,\mathrm{col}} = (1-\varepsilon)\,\mathit{PR}^{t}_i \]SMB and steady-state recycling have their own cycles; their pages say which basis they use.
Symbols
Units: "–" means dimensionless. Concentrations are in any unit you like (g/L, mol/L); \( q \) and \( q_{\mathrm{s}} \) are in the same unit, \( b \) in its inverse. Subscripts that are labels (cut, FB, SMB, col) are upright; \( i \) and \( j \) are component indices in elution order, \( k \) a zone index.
| Symbol | Unit | Definition |
|---|---|---|
| Unified Design operating parameters | ||
| \( s \) | – | Operating parameter of an event: liquid volume pumped per volume of stationary phase, scaled and aligned. On a chromatogram, the outlet axis \( s \) \( {}= \left(\frac{t - \Delta t^{\mathrm{F}}}{t_0} - 1\right)F^{-1} \). |
| \( s_{\mathrm{FB}} \) | – | Fixed-bed event of duration \( \Delta t \): \( Q\Delta t/((1-\varepsilon)V_{\mathrm{col}}) \) \( {}= (\Delta t/t_0)F^{-1} \). |
| \( s_{\mathrm{cut}} \) | – | Cut event at time \( t_{\mathrm{cut}} \): \( \left(\frac{t_{\mathrm{cut}} - \Delta t^{\mathrm{F}}}{t_0} - 1\right)F^{-1} \); 0 when the rear of a non-adsorbing tracer elutes. |
| \( s_{\mathrm{SMB}} \) | – | SMB event with switch time \( \Delta t_{\mathrm{switch}} \): \( \left(\frac{\Delta t_{\mathrm{switch}}}{t_0} - 1\right)F^{-1} \). Formally identical to \( m_j \) of Triangle Theory. |
| \( s_{\mathrm{I}}, \ldots, s_{\mathrm{IV}} \) | – | \( s_{\mathrm{SMB}} \) of zones I to IV of a four-zone SMB. |
| \( s^{\mathrm{FF}} \) | – | Fresh feed per cycle: \( Q\Delta t^{\mathrm{FF}}/((1-\varepsilon)V_{\mathrm{col}}) \) \( {}= (\Delta t^{\mathrm{FF}}/t_0)F^{-1} \). |
| \( s^{\mathrm{F}} \) | – | Column feed (fresh feed plus any recycle): \( (\Delta t^{\mathrm{F}}/t_0)F^{-1} \). In batch elution \( s^{\mathrm{F}} = s^{\mathrm{FF}} \). |
| \( s^{\mathrm{W}} \) | – | Size of a waste fraction, the FB event between the two cuts that bound it: \( s_{\mathrm{cut},3} - s_{\mathrm{cut},2} \). |
| \( S \) | – | Auxiliary parameter: \( S = s + s^{\mathrm{FF}} \) in fixed-bed processes, \( S = s + s^{\mathrm{FF}}/N_{\mathrm{SMB}} \) with SMB events. |
| \( S_{\mathrm{cut}} \) | – | \( s_{\mathrm{cut}} + s^{\mathrm{FF}} \) \( {}= \left(\frac{t_{\mathrm{cut}}}{t_0} - 1\right)F^{-1} \) in batch elution: the cut counted from the start of the feed. |
| \( S_{\mathrm{II}} \) | – | \( s_{\mathrm{II}} + s^{\mathrm{FF}}/N_{\mathrm{SMB}} \); in classical SMB \( S_{\mathrm{II}} = s_{\mathrm{III}} \). |
| \( N_{\mathrm{SMB}} \) | – | Number of SMB events in one repeating sequence (1 in classical SMB). |
| \( m_j \) | – | Flow-rate ratio of zone \( j \) in Triangle Theory; \( m_j = s_{\mathrm{SMB},j} \). |
| \( l_{j,k} \) | – | Distance component \( j \) moves in zone \( k \) during one SMB event (column shift included), per column length: \( \frac{s_{\mathrm{SMB},k} - H_j}{F^{-1} + H_j} \). |
| Times, flows and volumes | ||
| \( t \) | time | Time at the column outlet, from the start of the feed. |
| \( t_0 \) | time | Dead time, \( \varepsilon V_{\mathrm{col}}/Q \) (box above). |
| \( \Delta t^{\mathrm{F}} \) | time | Duration of the column feed, which may include recycled material. |
| \( \Delta t^{\mathrm{FF}} \) | time | Duration of the fresh feed. In batch elution \( \Delta t^{\mathrm{F}} = \Delta t^{\mathrm{FF}} \). |
| \( t_{\mathrm{cut}} \) | time | Time of a cut event at the column outlet. |
| \( \Delta t_{\mathrm{switch}} \) | time | Switch time of an SMB event. |
| \( t_{\mathrm{R},i} \) | time | Retention time of a small pulse of component \( i \), \( t_0(1 + FH_i) \) under ideal conditions. |
| \( s_{\mathrm{cycle}} \), \( t_{\mathrm{cycle}} \) | –; time | Cycle of stacked injections on the \( s \) axis and in time (box above). |
| \( Q \) | volume/ | Volumetric flow rate of the liquid during an event. |
| \( Q_{\mathrm{I}}, \ldots, Q_{\mathrm{IV}} \) | volume/ | Flow rates in zones I to IV of an SMB unit. |
| \( Q^{\mathrm{FF}} \), \( Q^{\mathrm{EL}} \), \( Q^{\mathrm{E}} \), \( Q^{\mathrm{R}} \), \( Q^{\mathrm{W}} \) | volume/ | External flows of an SMB unit: fresh feed, eluent, extract, raffinate, waste, in the notation of the papers. |
| \( V_{\mathrm{col}} \) | volume | Volume of one column (packed bed). |
| \( u \) | length/ | Interstitial velocity of the liquid, \( Q/(\varepsilon A) \), with \( A \) the cross-sectional area. |
| \( z, L \) | length | Axial position in the column; column length. |
| Column, phases and isotherms | ||
| \( \varepsilon \) | – | Total porosity: liquid volume reachable by the solutes, between and inside the particles, per column volume. |
| \( \varepsilon_{\mathrm{e}} \), \( \varepsilon_{\mathrm{p}} \) | – | External (interparticle) porosity; particle porosity. \( \varepsilon \) \( {}= \varepsilon_{\mathrm{e}} + (1-\varepsilon_{\mathrm{e}})\varepsilon_{\mathrm{p}} \). |
| \( F \) | – | Phase ratio, \( (1-\varepsilon)/\varepsilon \). |
| \( c_i \) | conc. | Concentration of component \( i \) in the liquid. |
| \( c_i^{\mathrm{FF}} \) | conc. | Concentration of component \( i \) in the fresh feed. |
| \( q_i \) | conc. | Concentration of component \( i \) in the stationary phase, per volume of stationary phase \( (1-\varepsilon)V_{\mathrm{col}} \). |
| \( H_i \) | – | Henry constant, the initial slope of the isotherm; \( q_{\mathrm{s},i} b_i \) for Langmuir. |
| \( q_{\mathrm{s},i} \) | conc. | Saturation capacity of component \( i \) in the competitive Langmuir isotherm (box above). |
| \( b_i \) | 1/conc. | Langmuir equilibrium constant. |
| \( \alpha \) | – | Separation factor, \( H_2/H_1 \). |
| \( \omega \) | – | Characteristic parameter of the \( \omega \) (or \( h \)) transformation of the competitive Langmuir isotherm (equilibrium theory). |
| NTP | – | Number of theoretical plates of a column, a measure of its efficiency (infinite under ideal conditions). |
| Purity and performance | ||
| \( \mathit{Pu}_i \) | – | Purity of the product fraction of component \( i \) (box above). |
| \( \mathit{Pu}_{i,\min} \) | – | Purity target of component \( i \). |
| \( \mathit{Pu}_i^{\mathrm{FF}} \) | – | Feed purity, \( c_i^{\mathrm{FF}}/(c_1^{\mathrm{FF}} + c_2^{\mathrm{FF}}) \). |
| \( Y_i \) | – | Yield of component \( i \) in its product fraction. |
| \( m_i \) | conc. | Product per cycle per volume of stationary phase, \( \int c_i\,\mathrm{d}s \) over the product fraction. |
| \( \mathit{PR}_i \) | conc. | Productivity per volume pumped, \( m_i/s_{\mathrm{cycle}} \). |
| \( \mathit{EC}_i \) | 1/conc. | Eluent consumption, \( (s_{\mathrm{cycle}} - s^{\mathrm{FF}})/m_i \). |
| \( \mathit{PR}^{t}_i \), \( \mathit{PR}^{t}_{i,\mathrm{col}} \) | conc./ | Productivity per time, per volume of stationary phase and per column volume. |
| Superscripts and subscripts, on any symbol \( x \) | ||
| \( x^{\mathrm{F}} \), \( x^{\mathrm{FF}} \) | Column feed (may include recycle); fresh feed to the process. | |
| \( x^{\mathrm{EL}} \), \( x^{\mathrm{W}} \) | Eluent; waste fraction or waste stream. | |
| \( x_{\mathrm{E}} \), \( x_{\mathrm{R}} \) | Extract and raffinate streams of an SMB unit. | |
| \( x_{\mathrm{I}}, \ldots, x_{\mathrm{IV}} \) | Zones of a four-zone SMB unit, numbered from the eluent inlet. | |
Further reading
- Siitonen, J., Sainio, T., Explicit equations for the height and position of the first component shock for binary mixtures with competitive Langmuir isotherms under ideal conditions, J. Chromatogr. A 1218 (2011) 6379–6387.
- Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
- Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
- Guiochon, G., Felinger, A., Shirazi, D.G., Katti, A.M., Fundamentals of Preparative and Nonlinear Chromatography, 2nd ed., Academic Press, Amsterdam (2006). ISBN 978-0-12-370537-2.
- Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.