Skip to the content
Unified Design Method Design of chromatographic separation processes

Example 8: steady-state recycling

In Example 3 the middle 0.4 of the outlet profile is discarded so that both products stay pure, and both yields drop to 71.4 %. Why not mix that middle fraction with the next fresh feed and inject it again? This is mixed-recycle steady-state recycling (SSR). With linear isotherms under ideal conditions every cycle of it can be computed exactly, and the result is instructive.

Symbols and “ideal conditions”: Notation and definitions. The theory behind this example: Waste and recycle fractions. Back to the Examples or the Theory.

System (as in Example 3). Linear isotherms, \(H_1 = 1.5\), \(H_2 = 2.5\); fresh feed \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\), richer in the first-eluting component; ideal conditions.

Example 3 (batch with a waste fraction). \(s^{\mathrm{FF}} = 1.4\); product 1 up to \(s_{\mathrm{cut}2} = 1.1\), waste from 1.1 to \(s_{\mathrm{cut}3} = 1.5\), product 2 after 1.5. Both products pure: 1.5 of component 1 and 1.0 of component 2 per cycle, while 0.6 of component 1 and 0.4 of component 2 are lost.

The process

Each cycle consists of the same events as Example 3, except that the middle fraction goes to a tank instead of the drain:

  1. FB event: inject the column feed, the content of the tank mixed with the fresh feed. Its size is \(s^{\mathrm{F}} = s^{\mathrm{FF}} + s^{\mathrm{R}}\).
  2. FB event: elute with eluent.
  3. Cut events at \(s_{\mathrm{cut}2}\) and \(s_{\mathrm{cut}3}\), on the \(s_{\mathrm{cut}}\) axis of this cycle's column feed: product 1 before \(s_{\mathrm{cut}2}\), the recycle fraction between the two cuts, product 2 after \(s_{\mathrm{cut}3}\). The recycle fraction is the difference of the two cut events, an FB event of size \(s^{\mathrm{R}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2}\).

The first cycle is plain batch elution of fresh feed (the tank is empty); its middle fraction fills the tank. From the second cycle on, the column feed is \(s^{\mathrm{F}} = s^{\mathrm{FF}} + s^{\mathrm{R}}\) every cycle. With linear isotherms each component leaves the column as a rectangle at its column-feed concentration \(c_i^{\mathrm{F}}\), between \(s_{\mathrm{cut}} = H_i - s^{\mathrm{F}}\) and \(H_i\), whatever the concentrations are. So every amount in every cycle is a width times a concentration, and the iteration is exact (the script uses rational arithmetic and checks every cycle against the ideal-model solver).

Three runs are compared:

The three SSR runs of this example. The cut-3 point is \((s_{\mathrm{cut}3},\, S_{\mathrm{cut}3} = s_{\mathrm{cut}3} + s^{\mathrm{FF}})\).
Run\(s^{\mathrm{FF}}\)\(s_{\mathrm{cut}2}\)\(s_{\mathrm{cut}3}\)\(s^{\mathrm{R}}\)\(s^{\mathrm{F}}\)Cut-3 point
A: fresh feed kept at 1.41.41.11.50.41.8(1.5, 2.9)
B: fresh feed reduced to 1.01.01.11.50.41.4(1.5, 2.5)
C: a point inside the triangle0.61.11.60.51.1(1.6, 2.2)

Run A: recycling with the same fresh feed

The first cycle is Example 3 itself: both products are pure, and the middle fraction, 0.6 of component 1 and 0.4 of component 2, goes to the tank. It has the feed composition, so in the second cycle the column feed is 1.4 of fresh feed plus 0.4 of recycle, both at concentrations 1.5 and 1, and \(s^{\mathrm{F}} = 1.8\). The bands now overlap from \(s_{\mathrm{cut}} = 2.5 - 1.8 = 0.7\) to 1.5, and the cut at 1.1 lets 0.4 of component 2 into product 1. From then on nothing changes: the recycle is again 0.6 of component 1 and 0.4 of component 2, the cyclic steady state is reached in the second cycle, and product 1 has a purity of 84.0 % (2.1 of component 1 and 0.4 of component 2). Product 2 stays pure, but only 71.4 % of component 2 reaches it.

Recycling has turned a yield problem into a purity problem. Moving the cuts does not help: as shown below, no pair of cuts gives two pure products at steady state with \(s^{\mathrm{FF}} = 1.4\).

The iteration to cyclic steady state

From the second cycle on, the column feed has a fixed size and only its concentrations change. Let \(L_i\) be the width of band \(i\) that falls inside the recycle window \([s_{\mathrm{cut}2}, s_{\mathrm{cut}3}]\). The tank then receives \(c_i^{\mathrm{F}} L_i\), and the next column feed has

\[ c_i^{\mathrm{F}}(k+1) = \frac{c_i^{\mathrm{FF}} s^{\mathrm{FF}} + L_i\, c_i^{\mathrm{F}}(k)}{s^{\mathrm{F}}}, \qquad c_i^{\mathrm{F}*} = \frac{c_i^{\mathrm{FF}} s^{\mathrm{FF}}}{s^{\mathrm{F}} - L_i}. \]

The distance to the steady state shrinks by the factor \(L_i/s^{\mathrm{F}}\) per cycle. In run B, \(L_1 = L_2 = 0.4\) and \(s^{\mathrm{F}} = 1.4\): component 1 is at its steady state, \(c_1^{\mathrm{F}} = 1.5\), from the second cycle on, and component 2 approaches its steady state as \(c_2^{\mathrm{F}} = 1 - (2/7)^{k-1}\) (0.714, 0.918, 0.977, 0.993, …), within \(10^{-6}\) by cycle 13. In run C, \(L_1 = 0.4\) and \(L_2 = 0.2\) with \(s^{\mathrm{F}} = 1.1\): the column feed of the second cycle is too rich in component 1 (1.364) and too lean in component 2 (0.545), and the two converge from opposite sides to \(c_1^{\mathrm{F}*} = 9/7 = 1.286\) and \(c_2^{\mathrm{F}*} = 2/3 = 0.667\), within \(10^{-6}\) by cycle 14. Both steady values lie below the fresh-feed concentrations: each band fills only part of the recycle window (0.4 and 0.2 of its 0.5), so the recycle dilutes both components. In runs B and C both products are pure in every cycle, because the band positions do not depend on the concentrations; only the amounts per cycle grow or shrink to their steady values.

Cycle by cycle (amounts per unit volume of stationary phase): the column feed, the amounts of components 1 and 2 in each fraction, and the purities of the products.
Cycle\(s^{\mathrm{F}}\)\(c_1^{\mathrm{F}}\)\(c_2^{\mathrm{F}}\)Product 1RecycleProduct 2\(\mathit{Pu}_1\) of product 1\(\mathit{Pu}_2\) of product 2
Figure 1. Left: the outlet profile of the first cycle (thin, dashed; this is plain batch elution of fresh feed) and at cyclic steady state (thick), with product 1 (blue band), the recycle fraction (grey band) and product 2 (red band). Right: the column-feed concentrations cycle by cycle (points) and their steady values (dashed lines). In run B, component 2 builds up in the loop while component 1 is at steady state from cycle 2. Cycle 1 is fresh feed only, so its points sit at the fresh-feed concentration. In run C the two components approach their steady values from opposite sides. In run A the steady state is reached at once, with component 2 in product 1.

The steady-state region against batch

At cyclic steady state the products of each run are exactly those of plain batch elution with one cut at \(s_{\mathrm{cut}3}\) and the same fresh feed \(s^{\mathrm{FF}}\): in run A, batch with one cut at 1.5 and \(s^{\mathrm{FF}} = 1.4\) also gives 2.1 + 0.4 in product 1 and 1.0 in product 2. The script confirms this in exact arithmetic for all three runs; Waste and recycle fractions derives it in general. The consequence: the steady-state region of SSR, drawn for the cut-3 point \((s_{\mathrm{cut}3}, S_{\mathrm{cut}3})\) on the same operating parameter plane, is the batch region, for any purity target and whatever the size of the recycle fraction. For two pure products,

\[ H_1 \le s_{\mathrm{cut}3} \le S_{\mathrm{cut}3} \le H_2, \qquad \text{so} \qquad s^{\mathrm{FF}} \le H_2 - H_1 = 1.0. \]

Figure 2 shows this. The batch regions come from the ideal-model solver; the SSR boundary points were found independently, by root finding on the exact steady-state purities of the recycling process with \(s^{\mathrm{R}} = 0.4\) (recycle sizes of 0.1 and 1.0 give the same points to within \(3 \times 10^{-15}\)). Run A lies above the triangle, which is why product 1 is impure. Run B sits on the vertex: the column feed is 1.4, the steady-state outlet profile is exactly that of Example 3, but only 1.0 of it is fresh feed. Run C lies inside.

Figure 2. The batch one-cut regions for purity targets of 100 % (triangle), 95 % and 90 % (shaded), and the boundaries of the SSR steady-state region at the same targets (open circles, computed independently for a recycle fraction of 0.4), on the \((s_{\mathrm{cut}3}, S_{\mathrm{cut}3})\) operating parameter plane. The circles lie on the batch boundaries. Also shown: the cut-3 points of runs A, B and C, and the two cut points of Example 3. Example 3's cut-2 point (1.1, 2.5) meets the batch-with-waste condition \(S_{\mathrm{cut}2} \le H_2\); run A, with the same cuts and fresh feed, has its cut-3 point at (1.5, 2.9), outside the triangle.

What recycling buys here

Per cycle, at steady state, amounts per unit volume of stationary phase. The width of the outlet profile (front of component 1 to end of component 2) is the least volume pumped per cycle, per unit volume of stationary phase, with stacked injections; SSR needs more, because the next column feed can be made up only after the recycle fraction has been collected.
OperationFresh feed \(s^{\mathrm{FF}}\)Column feed \(s^{\mathrm{F}}\)Product 1Product 2YieldsOutlet profile width
Batch, one cut at 1.5 (the tip)1.01.01.5, pure1.0, pure100 %, 100 %2.0
Example 3, batch with waste1.41.41.5, pure1.0, pure71.4 %, 71.4 %2.4
Run A, SSR1.41.82.5, 84.0 % pure1.0, pure100 %, 71.4 %2.8
Run B, SSR1.01.41.5, pure1.0, pure100 %, 100 %2.4
Run C, SSR0.61.10.9, pure0.6, pure100 %, 100 %2.1

Run B does what was hoped for: the same products per cycle as Example 3, from the same outlet profile, without losing any feed. Of the 1.4 that Example 3 injects, the 0.4 that was discarded is now recycled, so 1.0 of fresh feed per cycle gives 1.5 of component 1 and 1.0 of component 2, everything it contains. But batch elution at the tip of the triangle does the same, from the same fresh feed, with a narrower outlet profile and without a tank. Under ideal conditions with linear isotherms recycling therefore gains nothing over batch. The reason is the one Sainio (2021) gives for waste fractions: the unresolved middle has the feed composition, so sending it round again only adds volume.

So under ideal conditions SSR gives no performance benefit over batch elution. In practice it pays off: a real column can be run at a higher flow rate, and as dispersion grows, recycling keeps the yield high, because the widened unresolved zone goes round again instead of being discarded or sold as impurity. Variants, such as concentrating the recycle before it is mixed with the fresh feed, are outside this example. The Limits page discusses the non-ideal case; the feasible region of Figure 2 remains the reference.

Further reading

  1. Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
  2. Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
  3. Sainio, T., Kaspereit, M., Analysis of steady state recycling chromatography using equilibrium theory, Sep. Purif. Technol. 66 (2009) 9–18.
  4. Kaspereit, M., Sainio, T., Simplified design of steady-state recycling chromatography under ideal and nonideal conditions, Chem. Eng. Sci. 66 (2011) 5428–5438.
  5. Bailly, M., Tondeur, D., Recycle optimization in non-linear productive chromatography—I. Mixing recycle with fresh feed, Chem. Eng. Sci. 37 (1982) 1199–1212.
  6. Siitonen, J., Sainio, T., Kaspereit, M., Theoretical analysis of steady state recycling chromatography with solvent removal, Sep. Purif. Technol. 78 (2011) 21–32.

Disclaimer: No liability is assumed for correctness or completeness of data generated with the tools available on this website.