Skip to the content
Unified Design Method Design of chromatographic separation processes

Reduced purity and partial separation

Few industrial separations need two products at 100 % purity. A target of 95 % or 99 % often allows much more feed per cycle, and when the bands overlap you can either accept some impurity with one cut or discard the unresolved part with two cuts. The Unified Design method handles all of these with the same operating parameters on the same operating parameter planes.

Symbols, units and what “ideal conditions” means: see Notation and definitions. All results on this page are for ideal conditions; Limits of the ideal picture explains what changes with real columns. Back to the Theory overview.

Purity and yield of a fraction

A product fraction is the effluent collected between two cut events. Its content of component \(i\) is \(n_i = \int c_i \,\mathrm{d}s\), the amount per unit volume of stationary phase, \((1-\varepsilon)V_\mathrm{col}\). The purity and the yield of component \(i\) in that fraction are

\[ \mathit{Pu}_i = \frac{n_i}{n_1 + n_2}, \qquad Y_i = \frac{n_i}{c_i^{\mathrm{FF}} s^{\mathrm{FF}}}, \]

because \(c_i^{\mathrm{FF}} s^{\mathrm{FF}}\) is the amount injected per cycle. The feed itself has the purity \(\mathit{Pu}_i^{\mathrm{FF}} = c_i^{\mathrm{FF}}/(c_1^{\mathrm{FF}} + c_2^{\mathrm{FF}})\). A purity target \(\mathit{Pu}_{i,\mathrm{min}}\) is meaningful only above the feed purity: a target at or below it is met without any separation.

Components are numbered in elution order, \(H_1 < H_2\). Product 1 is the first fraction, product 2 the last. Two properties of the ideal outlet profile make the design simple:

One cut, linear isotherms

With linear isotherms each component leaves the column as a rectangle, component \(i\) between \(s_{\mathrm{cut}} = H_i - s^{\mathrm{FF}}\) and \(H_i\). Below \(s^{\mathrm{FF}} = H_2 - H_1\) the bands are separated, and any cut between them gives two pure products. Above it the bands overlap over a width \(s^{\mathrm{FF}} - (H_2 - H_1)\), where the effluent has the feed composition. A cut inside the overlap gives the purities (Sainio 2021, Eqs. S15 and S16)

\[ \mathit{Pu}_1^{(1)} = \left[ 1 + \frac{\mathit{Pu}_2^{\mathrm{FF}}}{\mathit{Pu}_1^{\mathrm{FF}}}\,\frac{S_{\mathrm{cut}} - H_2}{S_{\mathrm{cut}} - H_1} \right]^{-1}, \qquad \mathit{Pu}_2^{(2)} = \left[ 1 + \frac{\mathit{Pu}_1^{\mathrm{FF}}}{\mathit{Pu}_2^{\mathrm{FF}}}\,\frac{H_1 - s_{\mathrm{cut}}}{H_2 - s_{\mathrm{cut}}} \right]^{-1}. \]

The purity of product 1 depends on \(S_{\mathrm{cut}} = s_{\mathrm{cut}} + s^{\mathrm{FF}}\) only, that of product 2 on \(s_{\mathrm{cut}}\) only. On the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) operating parameter plane the two targets are therefore a horizontal and a vertical line, which meet at the tip (Sainio 2021, Eqs. 27 and 28)

\[ s_{\mathrm{cut}}^{*} = H_2 - (H_2 - H_1)\,\frac{\mathit{Pu}_{2,\mathrm{min}}\,\mathit{Pu}_1^{\mathrm{FF}}}{\mathit{Pu}_{2,\mathrm{min}} - \mathit{Pu}_2^{\mathrm{FF}}}, \qquad S_{\mathrm{cut}}^{*} = H_1 + (H_2 - H_1)\,\frac{\mathit{Pu}_{1,\mathrm{min}}\,\mathit{Pu}_2^{\mathrm{FF}}}{\mathit{Pu}_{1,\mathrm{min}} - \mathit{Pu}_1^{\mathrm{FF}}}. \]

The largest feed per cycle is \(s^{\mathrm{FF}*} = S_{\mathrm{cut}}^{*} - s_{\mathrm{cut}}^{*}\). Below the tip the region is a pentagon: the complete-separation triangle, widened on the left by a band where product 1 is pure and product 2 meets its target, and on top by a band where product 2 is pure and product 1 meets its target. Under ideal conditions the classical four-zone SMB has exactly the same region on the same operating parameter plane, with \((s_\mathrm{II}, S_\mathrm{II})\) in place of \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\), provided zones I and IV regenerate the adsorbent and the eluent completely (Sainio 2021, Section 4). Rajendran (2008) derived the same boundaries within Triangle Theory, with a different definition of purity (Sainio 2021, Section 4).

Tips of the one-cut regions of Figure 1 (linear, \(H_1 = 1.5\), \(H_2 = 2.5\), \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\), equal targets). Computed from the exact outlet profiles; the closed forms above give the same values.
Purity targets\(s_{\mathrm{cut}}^{*}\)\(S_{\mathrm{cut}}^{*}\)\(s^{\mathrm{FF}*}\)Feed per cycle vs 100 %
100 %1.52.51.0–
99 %1.49322.51541.0222+2.2 %
95 %1.46362.58571.1221+12.2 %
90 %1.422.71.28+28 %

For example, with 90 % targets and \(s^{\mathrm{FF}} = 1.0\) any cut from 1.426 to 1.667 is feasible, and the feed per cycle can be raised to 1.28, 28 % more than for two pure products. Example 2 works through this case.

Figure 1. Linear isotherms (\(H_1 = 1.5\), \(H_2 = 2.5\), \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\)): one-cut regions for purity targets of 100, 99, 95 and 90 % for both products. The 100 % region is the triangle with corners (1.5, 1.5), (2.5, 2.5) and (1.5, 2.5). Each lower target adds a band on the left and on top, and moves the tip up and to the left along a straight line; at 90 % the tip is at (1.375, 2.625).

One cut, competitive Langmuir isotherms

With competitive Langmuir isotherms the bands change shape with the feed amount: shocks at the front, simple waves at the rear, and displacement of component 1 by component 2. There is no closed form for the reduced-purity boundaries, but the outlet profile itself is exact (Siitonen and Sainio, 2011), and so are the amounts in any fraction. The boundaries follow by root finding on these exact amounts. The outer boundaries are curved at small \(s^{\mathrm{FF}}\), because there the cuts fall on the simple waves of the pure components (Sainio 2021, Section 3.4).

For the system of Figure 2 (\(q_\mathrm{s} = 10\) for both components, \(b_1 = 0.15\), \(b_2 = 0.25\), so \(H_1 = 1.5\) and \(H_2 = 2.5\) as in Figure 1, and \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\)), the tip moves from \(s^{\mathrm{FF}} = 0.5078\) at 100 % (vertex \(w\) of Triangle Theory, at \((1.3096, 1.8174)\)) to 0.5607 at 99 %, 0.6695 at 95 % and 0.8068 at 90 %. Relaxing both targets to 90 % allows 59 % more feed per cycle. Note also that 99 % is not “almost 100 %” here: its tip lies 10.4 % above the exact touching-bands value.

Under ideal conditions this region is also the region of the classical four-zone SMB for partial separations with Langmuir isotherms, provided zones I and IV regenerate completely (Sainio 2021, Section 4).

Figure 2. Competitive Langmuir isotherms (\(q_\mathrm{s} = 10\), \(b_1 = 0.15\), \(b_2 = 0.25\), \(c_1^{\mathrm{FF}} = 1.5\), \(c_2^{\mathrm{FF}} = 1\)): one-cut regions for purity targets of 100, 99, 95 and 90 %. The regions are smaller than in Figure 1: the rear of each band is a dispersive simple wave, so the bands need more room on the \(s\) axis. The 100 % region is the Triangle Theory region: straight from (1.5, 1.5) to the vertex \(w\), straight from \(w\) to \(r = (1.8367, 2.0408)\), and curved from \(r\) down to (2.5, 2.5). The lower targets add bands whose outer boundaries are curved near the diagonal.

Overlapping bands: one cut or two

Above the tip, no single cut meets both targets. One option is to inject less. The other is to cut twice and discard the middle of the profile as a waste fraction. Because the purity of product 1 depends only on the cut that ends it, and the purity of product 2 only on the cut that starts it, the two cuts can be chosen independently:

If \(s_{\mathrm{cut}2} \ge s_{\mathrm{cut}3}\), one cut anywhere between them is enough. Otherwise the effluent between them is waste, and this is the smallest waste fraction that meets both targets.

The waste fraction is a fixed-bed event

A cut event is instantaneous, so it has no volume. The difference of two cut events, however, is the volume of liquid that flowed out between them: an FB event (Sainio 2016, Fig. 1A; Sainio 2021, Section 5.1). With the definitions of \(s_{\mathrm{cut}}\) and \(s_{\mathrm{FB}}\),

\[ s^{\mathrm{W}} = s_{\mathrm{cut}3} - s_{\mathrm{cut}2} = \frac{Q\,\left(t_{\mathrm{cut}3} - t_{\mathrm{cut}2}\right)}{(1-\varepsilon)V_\mathrm{col}}, \qquad V^{\mathrm{W}} = (1-\varepsilon)V_\mathrm{col}\, s^{\mathrm{W}}. \]

A batch process with a waste fraction is represented by two operating points, \((s_{\mathrm{cut}2}, S_{\mathrm{cut}2})\) and \((s_{\mathrm{cut}3}, S_{\mathrm{cut}3})\). Both belong to the same injection, so both lie at the distance \(s^{\mathrm{FF}}\) above the diagonal. For two pure products with linear isotherms the conditions are (Sainio 2021, Eqs. 35 to 37)

\[ H_1 - s^{\mathrm{FF}} \le s_{\mathrm{cut}2} \le s_{\mathrm{cut}3}, \qquad H_1 \le S_{\mathrm{cut}2} \le H_2, \qquad H_1 \le s_{\mathrm{cut}3} \le H_2 . \]

The smallest waste fraction puts the two points on the extensions of the triangle's sides, \(S_{\mathrm{cut}2} = H_2\) and \(s_{\mathrm{cut}3} = H_1\), so \(s^{\mathrm{W}} = s^{\mathrm{FF}} - (H_2 - H_1)\). For reduced targets the points move to the extensions of the reduced-purity boundaries, \(S_{\mathrm{cut}2} = S_{\mathrm{cut}}^{*}\) and \(s_{\mathrm{cut}3} = s_{\mathrm{cut}}^{*}\), and \(s^{\mathrm{W}} = s^{\mathrm{FF}} - s^{\mathrm{FF}*}\): with linear isotherms, every unit of feed beyond the tip goes to waste. There is no upper limit to \(s^{\mathrm{FF}}\) with a waste fraction.

With the linear system of Figure 1 and \(s^{\mathrm{FF}} = 1.4\): for 100 % the cuts are at 1.1 and 1.5, \(s^{\mathrm{W}} = 0.4\), and both yields are 71.4 %, as in Example 3. For 90 % the cuts are at 1.30 and 1.42, \(s^{\mathrm{W}} = 0.12\), and the yields are 85.7 % and 77.1 %.

Fractionfrom \(s_{\mathrm{cut}}\)to \(s_{\mathrm{cut}}\)\(\mathit{Pu}_1\)\(\mathit{Pu}_2\)\(Y_1\)\(Y_2\)
Figure 3. One cut or two cuts. Left: the outlet profile on the \(s_{\mathrm{cut}}\) axis (component 1 blue, component 2 red) with product 1 (blue band), the waste fraction (grey band) and product 2 (red band). Right: the same cut events as operating points on the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) operating parameter plane, with the one-cut feasible region of the chosen target. Below the tip one cut suffices, and the feasible cuts form the shaded interval (the readout uses its middle). Above the tip the two cuts of the smallest waste fraction appear. Both points lie on the same line parallel to the diagonal; with linear isotherms one lies on the horizontal and the other on the vertical extension of the region's sides. Start with the linear system at 100 % and \(s^{\mathrm{FF}} = 1.4\): the waste fraction runs from 1.1 to 1.5.

Is the waste worth it?

Under ideal conditions, with linear isotherms, no. The waste fraction has the feed composition, the products per cycle stop growing at the tip, and only the cycle gets longer (Sainio 2021, Section 5.1). With competitive Langmuir isotherms there is a gain for the less retained component: displacement enriches its pure plateau. In the Langmuir system of Figure 2 with 100 % targets, product 1 grows from 0.762 per cycle at the touching bands to 1.017 once the feed plateau appears (\(s^{\mathrm{FF}} \ge 0.905\)), while product 2 stays at 0.508. Its productivity per volume pumped is highest at \(s^{\mathrm{FF}} \approx 0.74\), 14.2 % above the touching-bands value; for product 2 the best is the touching bands, without waste. Productivity here is per volume pumped with stacked injections, as on the design tool.

The picture changes in real columns. Dispersion smears the bands into each other, and discarding the unresolved middle can then raise purity and productivity considerably (Sainio 2021, Fig. 7). The ideal regions remain the reference against which such gains are judged.

Figure 4. Left: the smallest waste fraction \(s^{\mathrm{W}}\) against the feed per cycle, for 100 % (solid) and 95 % (dashed) targets. It is zero up to the tip of the one-cut region. With linear isotherms it then grows exactly as fast as the feed; with Langmuir isotherms it first grows faster, and as fast as the feed once the feed plateau appears. Right: productivity per volume pumped (amount of product per cycle divided by the volume pumped per cycle, stacked injections) of product 1 (blue) and product 2 (red). With linear isotherms neither product gains from a waste fraction. With Langmuir isotherms product 1 gains from a waste fraction; product 2 is best without one. Where one cut suffices, the curves use the middle of the feasible interval.

SMB with a waste stream

The same idea carries over to SMB. Sainio (2021, Section 5.2) placed a waste outlet in a four-zone or five-zone unit and wrote the closure of the central zones as \(s^{\mathrm{FF}} - s^{\mathrm{W}} = s_\mathrm{III} - s_\mathrm{II}\), using the rule that the difference of two \(s\)-parameters is an FB event. With the new parameter \(s_3 = s_\mathrm{II} - s^{\mathrm{W}}\), the zone III parameter becomes \(S_3 = s_3 + s^{\mathrm{FF}} = s_\mathrm{III}\). For linear isotherms under ideal conditions, the limits for \(s_\mathrm{II}\) and \(S_3\) are those of \(s_{\mathrm{cut}3}\) and \(S_{\mathrm{cut}2}\) in batch with a waste fraction. A five-zone unit with the waste outlet between the fresh feed and the raffinate can reproduce any such batch operation; with dispersion, no position of the waste outlet improved the performance for both products at once. The Event algebra page shows how these parameters are composed, and Waste and recycle fractions what happens when the middle fraction is recycled instead of discarded.

Further reading

  1. Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.
  2. Siitonen, J., Sainio, T., Rajendran, A., Design of batch chromatography for separation of binary mixtures under reduced purity requirements, J. Chromatogr. A 1286 (2013) 55–68.
  3. Siitonen, J., Sainio, T., Explicit equations for the height and position of the first component shock for binary mixtures with competitive Langmuir isotherms under ideal conditions, J. Chromatogr. A 1218 (2011) 6379–6387.
  4. Rajendran, A., Equilibrium theory-based design of simulated moving bed processes under reduced purity requirements. Linear isotherms, J. Chromatogr. A 1185 (2008) 216–222.
  5. Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
  6. Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.

Disclaimer: No liability is assumed for correctness or completeness of data generated with the tools available on this website.

© Tuomo Sainio, 2021-2026.