Example 9: case study, glucose and fructose
Separating fructose from glucose on a calcium-form cation-exchange resin is one of the classic industrial SMB applications, in use since the 1970s. This case study goes from published isotherm and column data to a UD design and the flow rates of a real pilot unit, and compares the result with what was actually run.
Theory: From parameters to equipment · Symbols: Notation · Interactive: Design tool
The data
| Resin | Dowex Monosphere 99/Ca, gel type, Ca2+ form, particle diameter 320 µm |
|---|---|
| Columns | 12 columns, 26 mm inner diameter, bed length 0.29 m; three columns per zone |
| Porosities | bed (between the particles) \(\varepsilon_{\mathrm{b}} = 0.4\), particle \(\varepsilon_{\mathrm{p}} = 0.1\) |
| Isotherms at 50 °C | linear; adsorbed amount per particle volume over the concentration in the pore liquid: \(K = 0.17\) (glucose) and 0.43 (fructose); with the pore liquid counted in, \(K' = K + \varepsilon_{\mathrm{p}} = 0.27\) and 0.53 |
| Feed | 40 g/L glucose and 40 g/L fructose |
| Pilot SMB runs | switch time 198 s; zone flows \(Q_{\mathrm{II}} = 4.65\), \(Q_{\mathrm{III}} = 5.21\), \(Q_{\mathrm{IV}} = 4.0\) and \(Q_{\mathrm{I}} = 5.67\) to \(6.38 \times 10^{-7}\) m³/s; target purity at least 90 % in both products |
| Measured purities | runs C and D: fructose in the extract 94.9 % and 96.5 %, glucose in the raffinate 92.7 % and 91.2 % |
The question: what does UD make of these data, which flow rates follow for this pilot unit, and how does the design compare with the conditions that were run?
Solution
Step 1: the data on the UD basis
Glucose is less retained, so it is component 1 and fructose component 2. On this site \(\varepsilon\) is the total porosity (the liquid between and inside the particles) and \(q\) is counted per volume of the stationary phase \((1 - \varepsilon)V_{\mathrm{col}}\), the solid that remains (Notation). For porous particles,
\[ \begin{aligned} \varepsilon &= \varepsilon_{\mathrm{b}} + (1 - \varepsilon_{\mathrm{b}})\,\varepsilon_{\mathrm{p}} = 0.46 , \\ H_i &= \frac{K_i}{1 - \varepsilon_{\mathrm{p}}} , \end{aligned} \]so \(H_1 = 0.1889\), \(H_2 = 0.4778\) and \(F = (1 - \varepsilon)/\varepsilon = 1.174\). As a check, the retention volume per column volume, \(\varepsilon + (1 - \varepsilon)H_i\), is 0.562 for glucose and 0.718 for fructose, exactly what the paper's own basis gives, \(\varepsilon_{\mathrm{b}} + (1 - \varepsilon_{\mathrm{b}})K'_i\).
Which porosity? The paper uses the bed porosity 0.4 with \(K'\), counting the pore liquid with the particles (\(F = 1.5\)). That basis is just as consistent: every \(s\) value on it maps to this page's by \(s \mapsto (s - \varepsilon_{\mathrm{p}})/(1 - \varepsilon_{\mathrm{p}})\), the Henry constants included, so the feasible region and the operating point keep their places and every flow rate and time comes out the same. Two things do change. The ratio of the Henry constants is 2.53 on this page's basis and 1.96 on the paper's, so such ratios must not be compared across bases. And mixing the bases, for example the bed porosity with Henry constants on the total-porosity basis, shifts the region: always take \(\varepsilon\) and \(H\) together.
For nonlinear isotherms, prefer the total-porosity basis: on the bed-porosity basis the pore liquid adds a linear term \(\varepsilon_{\mathrm{p}} c\) to the isotherm, and a Langmuir isotherm no longer stays Langmuir.
Step 2: the feasible region
The isotherms are linear, so the region of complete separation is the triangle of the simple example. On the \((s_{\mathrm{II}}, s_{\mathrm{III}})\) operating parameter plane of the SMB, which is the \((s_{\mathrm{cut}}, S_{\mathrm{cut}})\) plane of batch, its vertex is \(w = (H_1, H_2) = (0.1889, 0.4778)\), and the largest feed is \(s^{\mathrm{FF}} = H_2 - H_1 = 0.2889\). The authors' target, 90 % in both products with a 1:1 feed, allows more under ideal conditions: by the formulas of Example 2 the tip is at \((0.153, 0.514)\), with \(s^{\mathrm{FF}} = 0.361\).
Step 3: where the pilot unit was run
Under ideal conditions the optimum is the vertex \(w\). The pilot columns are not ideal: 320 µm gel particles with slow intraparticle mass transfer in short columns. Azevedo and Rodrigues therefore chose the operating point by detailed simulation of the non-ideal unit. Converted with the switch time and the column volume (Step 4), their zone flows give
\[ \begin{aligned} s_{\mathrm{II}} &= 0.256 , \qquad s_{\mathrm{III}} = 0.389 , \\ s^{\mathrm{FF}} &= s_{\mathrm{III}} - s_{\mathrm{II}} = 0.133 , \end{aligned} \]and \(s_{\mathrm{IV}} = 0.101\), with \(s_{\mathrm{I}}\) from 0.498 (run A) to 0.667 (run D). On the paper's own basis the same operating point is \((0.330, 0.450)\) with \(s^{\mathrm{FF}} = 0.120\); these are the Triangle Theory parameters \(m_j = \gamma_j/\nu\) of the paper's velocity ratios \(\gamma_j\) and \(\nu = (1 - \varepsilon_{\mathrm{b}})/\varepsilon_{\mathrm{b}}\). The point lies inside the triangle, 0.067 to the right of its left side and 0.089 below its top, and it uses 46 % of the ideal maximum feed. Zones I and IV keep to their ideal limits, \(s_{\mathrm{I}} \ge H_2\) and \(s_{\mathrm{IV}} \le H_1\), in every run.
Step 4: flow rates for the pilot unit
With \(V_{\mathrm{col}} = 154.0\) mL per column (\(\varepsilon V_{\mathrm{col}} = 70.8\) mL, \((1 - \varepsilon)V_{\mathrm{col}} = 83.1\) mL) and the switch time of 198 s, each zone flow follows from the definition of \(s_{\mathrm{SMB}}\) (From parameters to equipment):
\[ Q_j = \frac{\varepsilon V_{\mathrm{col}} + (1 - \varepsilon)V_{\mathrm{col}}\, s_j}{\Delta t_{\mathrm{switch}}} . \]With three columns per zone the conditions are the same per column. The table compares the ideal vertex \(w\) with the pilot runs, with zones I and IV as in run C:
| mL/min | Ideal vertex \(w\) | Pilot runs (run C) |
|---|---|---|
| \(s_{\mathrm{II}}\), \(s_{\mathrm{III}}\) | 0.1889, 0.4778 | 0.256, 0.389 |
| Zone I, \(Q_{\mathrm{I}}\) (\(s_{\mathrm{I}} = 0.627\)) | 37.26 | 37.26 |
| Zone II, \(Q_{\mathrm{II}}\) | 26.22 | 27.90 |
| Zone III, \(Q_{\mathrm{III}}\) | 33.50 | 31.26 |
| Zone IV, \(Q_{\mathrm{IV}}\) (\(s_{\mathrm{IV}} = 0.101\)) | 24.00 | 24.00 |
| Eluent, \(Q^{\mathrm{EL}} = Q_{\mathrm{I}} - Q_{\mathrm{IV}}\) | 13.26 | 13.26 |
| Extract, \(Q^{\mathrm{E}} = Q_{\mathrm{I}} - Q_{\mathrm{II}}\) | 11.04 | 9.36 |
| Feed, \(Q^{\mathrm{FF}} = Q_{\mathrm{III}} - Q_{\mathrm{II}}\) | 7.28 | 3.36 |
| Raffinate, \(Q^{\mathrm{R}} = Q_{\mathrm{III}} - Q_{\mathrm{IV}}\) | 9.50 | 7.26 |
For the pilot runs the formula returns the published flows exactly (\(4.65\), \(5.21\), \(4.0\) and \(6.21 \times 10^{-7}\) m³/s, feed \(0.56\) and raffinate \(1.21 \times 10^{-7}\) m³/s), which confirms the conversion. At \(w\) the unit would take 2.17 times as much feed. At 100 % recovery the pilot feed corresponds to 7.27 kg of each sugar per m³ of resin per hour; the authors measured 6.47 to 6.66 for fructose and 6.54 to 7.10 for glucose in runs C and D. At \(w\) the ideal figure would be 15.8.
Step 5: a batch test on one column
The same operating point can be tried first on a single column (Example 5). At 24 mL/min, the zone IV flow of the pilot runs, \(t_0 = \varepsilon V_{\mathrm{col}}/Q = 2.95\) min. With \(s_{\mathrm{cut}} = s_{\mathrm{II}} = 0.256\) and \(s^{\mathrm{FF}} = 0.133\): inject for \(\Delta t^{\mathrm{FF}} = s^{\mathrm{FF}} t_0 F\), 28 s or 11.1 mL (the feed of one SMB switch), and cut at \(t_{\mathrm{cut}} = \Delta t^{\mathrm{FF}} + t_0(1 + F s_{\mathrm{cut}}) = 4.30\) min. Ideally glucose leaves from 3.61 to 4.07 min and fructose from 4.61 to 5.07 min, and the next injection can follow every 1.46 min.
Step 6: what the experiments showed
At an operating point that, ideally, gives 100 % purity with less than half of the maximum feed, the pilot unit delivered 91 % to 97 % in runs C and D. In runs A and B, with \(s_{\mathrm{I}} = 0.498\) and 0.556, the raffinate reached only 85.5 % and 87.8 %, although both values meet the ideal limit \(s_{\mathrm{I}} \ge H_2\): zone I needs a margin too. The ideal model would even allow 90 %/90 % at 2.7 times this feed. The difference is the price of the slow mass transfer in the 320 µm gel particles and of the low column efficiency; the authors also traced part of the contamination to a small dead volume in the valves between the columns. UD gives the map, the optimum and the upper bound in minutes from two Henry constants, the porosity and the column size. How far inside the triangle a real plant must stay has to come from experiments or from non-ideal models (Limits of the ideal picture).
Try it yourself
In the design tool, enter the linear isotherm \(H_1 = 0.1889\), \(H_2 = 0.4778\), feed 40 and 40, purity targets 0.9 and 0.9, and the column \(\varepsilon = 0.46\), \(t_0 = 2.95\) min. Put the operating point at (0.256, 0.133) to see Figure 2, then move it towards the tip.
Further reading
- Azevedo, D.C.S., Rodrigues, A.E., Fructose–glucose separation in a SMB pilot unit: Modeling, simulation, design, and operation, AIChE J. 47 (2001) 2042–2051.
- Storti, G., Mazzotti, M., Morbidelli, M., Carrà, S., Robust design of binary countercurrent adsorption separation processes, AIChE J. 39 (1993) 471–492.
- Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.
- Sainio, T., Unified design of chromatographic separation processes: Partial separations and waste fractions, Chem. Eng. Sci. 234 (2021) 116457. Open access.