Example 6: centre cut of a ternary mixture
When the product elutes between two impurities, one injection has to give three clean fractions. How much feed can a batch column take, and which pair of components decides it?
This example answers both questions for linear isotherms under ideal conditions, where the answers are exact, and then asks what changes if only the middle component is worth anything. The theory is on the Ternary separations page; symbols are on the Notation page.
The system
Three components with linear isotherms and Henry constants \( H_1 = 1.0 \), \( H_2 = 1.8 \) and \( H_3 = 3.0 \). The first-eluting component is the most concentrated in the feed: \( c^{\mathrm{FF}}_1 = 1.5 \) and \( c^{\mathrm{FF}}_2 = c^{\mathrm{FF}}_3 = 1 \) (any unit, for example g/L). The differences are \( H_2 - H_1 = 0.8 \) and \( H_3 - H_2 = 1.2 \).
A feed of size \( s^{\mathrm{FF}} \) gives three rectangular bands. On the \( s_{\mathrm{cut}} \) axis, which counts from the end of the injection (in batch elution \( \Delta t^{\mathrm{F}} = \Delta t^{\mathrm{FF}} \)), band \( j \) runs from its front at \( H_j - s^{\mathrm{FF}} \) to its rear at \( H_j \).
With linear isotherms the components do not affect each other, so the feed concentrations only set the heights of the bands: 1.5 for band 1, 1 for bands 2 and 3. The cut limits and the yields below do not depend on them. What does is the purity of a fraction that holds two components.
Three pure fractions
The middle fraction is collected between two cuts. The cut \( s_{\mathrm{cut}2} \) must come after the rear of band 1 and before the front of band 2, and \( s_{\mathrm{cut}3} \) after the rear of band 2 and before the front of band 3:
The first interval exists up to \( s^{\mathrm{FF}} = 0.8 \), the second up to 1.2. Both cuts belong to the same injection, so three pure fractions need
The pair 1/2, with the smaller difference of Henry constants, is the bottleneck. The pair 2/3 could take half as much feed again, but that room cannot be used without spoiling the first cut. (The first and the last cut, which start and end the collection, only have to lie outside the bands: \( s_{\mathrm{cut}1} \le 1.0 - s^{\mathrm{FF}} \) and \( s_{\mathrm{cut}4} \ge 3.0 \).)
Two triangles on one \( s^{\mathrm{FF}} \) axis
Move the slider. The upper chart has both triangles on the same operating parameter plane, \( (s_{\mathrm{cut}}, s^{\mathrm{FF}}) \): the left one holds the allowed \( s_{\mathrm{cut}2} \), the right one the allowed \( s_{\mathrm{cut}3} \). The horizontal line is the chosen \( s^{\mathrm{FF}} \); where it crosses a triangle, the thick segment is the interval for that cut, and the dots are the cuts drawn below, in the middle of each interval. The chromatogram uses the same \( s_{\mathrm{cut}} \) axis, so each cut line sits right under its dot.
At \( s^{\mathrm{FF}} = 0.50 \): \( s_{\mathrm{cut}2} \) from 1.0 to 1.3, \( s_{\mathrm{cut}3} \) from 1.8 to 2.5; three pure fractions.
| Fraction | From \( s_{\mathrm{cut}} \) | To \( s_{\mathrm{cut}} \) | Purity | Yield |
|---|---|---|---|---|
| 1 | start | 1.15 | 100.0 % | 100.0 % |
| 2 | 1.15 | 2.15 | 100.0 % | 100.0 % |
| 3 | 2.15 | end | 100.0 % | 100.0 % |
Without the slider, four feeds tell the story:
| \( s^{\mathrm{FF}} \) | \( s_{\mathrm{cut}2} \) allowed | \( s_{\mathrm{cut}3} \) allowed | Cuts | Purity of fraction 1 | Yield of 2 |
|---|---|---|---|---|---|
| 0.4 | 1.0 to 1.4 | 1.8 to 2.6 | 1.2, 2.2 | 100 % | 100 % |
| 0.8 | 1.0 only | 1.8 to 2.2 | 1.0, 2.0 | 100 % | 100 % |
| 1.0 | none | 1.8 to 2.0 | 1.0, 1.9 | 88.2 % | 80.0 % |
| 1.2 | none | 1.8 only | 1.0, 1.8 | 81.8 % | 66.7 % |
To set a real column, convert the cuts to times with \( t_{\mathrm{cut}} = t_0\,(1 + F S_{\mathrm{cut}}) \), where \( S_{\mathrm{cut}} = s_{\mathrm{cut}} + s^{\mathrm{FF}} \), and the feed with \( \Delta t^{\mathrm{FF}} = t_0 F s^{\mathrm{FF}} \) (see From dimensionless parameters to equipment). On the \( (s, S) \) operating parameter plane the two cuts are the points \( (s_{\mathrm{cut}2}, S_{\mathrm{cut}2}) \) and \( (s_{\mathrm{cut}3}, S_{\mathrm{cut}3}) \), both \( s^{\mathrm{FF}} \) above the diagonal. Because \( H_2 - H_1 < H_3 - H_2 \), the region of the pair 2/3 is cut off at 0.8 above the diagonal and has four sides, as in Figure 1 of the theory page.
Extension: only component 2 is valuable
Suppose components 1 and 3 are impurities. Then fraction 1 does not have to be pure, and the first cut can go to the rear of band 1, \( s_{\mathrm{cut}2} = H_1 = 1.0 \), whatever the overlap: everything before it is waste. The waste goes on the side of component 1 because the pair 1/2 is the bottleneck; waste on the side of component 3 would not let the feed grow at all. Fraction 3 stays pure up to \( s^{\mathrm{FF}} = 1.2 \).
The catch is in the band algebra. Pure 2 can only be collected between the rear of band 1 and the rear of band 2, so one injection never gives more than \( c^{\mathrm{FF}}_2 (H_2 - H_1) = 0.8 \) of pure component 2, however large the feed. Above \( s^{\mathrm{FF}} = 0.8 \) the extra feed of component 2 only ends up in the waste, and the yield falls as \( 0.8/s^{\mathrm{FF}} \): to 80 % at 1.0 and 66.7 % at 1.2. Beyond 1.2 the front of band 3 also cuts into the middle fraction, and the amount falls too.
So under ideal conditions a larger injection with a waste cut does not pay. What does pay, when both 1 and 3 are waste, is to stack the injections closer: the rear of band 3 of one injection and the front of band 1 of the next may then leave in one shared waste fraction. With stacked injections (the basis of the productivity and eluent consumption on this site), Table 3 compares the options; \( s_{\mathrm{cycle}} \) is the liquid pumped per cycle per volume of stationary phase.
| Cutting | \( s^{\mathrm{FF}} \) | Cuts | Yield of 2 | \( s_{\mathrm{cycle}} \) | Productivity | Eluent consumption |
|---|---|---|---|---|---|---|
| Three pure fractions | 0.8 | 1.0, 2.0 | 100 % | 2.8 | 0.286 | 2.5 |
| Waste on the side of 1 | 1.0 | 1.0, 1.9 | 80 % | 3.0 | 0.267 | 2.5 |
| Waste on the side of 1 | 1.2 | 1.0, 1.8 | 66.7 % | 3.2 | 0.250 | 2.5 |
| 1 and 3 in one shared waste fraction | 0.8 | 1.0, 1.8 | 100 % | 2.0 | 0.400 | 1.5 |
With three pure products the cycle must end when band 3 has left, \( s_{\mathrm{cycle}} = H_3 - H_1 + s^{\mathrm{FF}} \). Sharing the waste fraction shortens the cycle from 2.8 to 2.0 at full yield, which raises the productivity of component 2 by 40 % and cuts its eluent consumption from 2.5 to 1.5. No larger feed does better: the search over all feeds and cuts in the script behind this page finds the same productivity, 0.400, as its maximum. In a real column, with finite efficiency, the bands have tails and every one of these margins shrinks (see Limits of the ideal picture).
What this example shows
- Three pure fractions: \( s^{\mathrm{FF}} \le \min(H_2 - H_1, H_3 - H_2) = 0.8 \), set by the pair with the smaller difference of Henry constants.
- Pure middle component per injection is capped at \( c^{\mathrm{FF}}_2 \min(H_2 - H_1, H_3 - H_2) \); overloading with a waste cut only lowers the yield.
- If the outer components are waste, the gain is in the cycle, not in the injection.
Theory: ternary separations · Example 7: the same system in SMB units · Notation · All examples
Further reading
- Sainio, T., Unified Design of chromatographic processes with timed events: Separation of ternary mixtures, Chem. Eng. Sci. 152 (2016) 547–567.
- Siitonen, J., Sainio, T., Unified design of chromatographic separation processes, Chem. Eng. Sci. 122 (2015) 436–451.
- Siitonen, J., Sainio, T., Explicit equations for the height and position of the first component shock for binary mixtures with competitive Langmuir isotherms under ideal conditions, J. Chromatogr. A 1218 (2011) 6379–6387.